TA-05/C
ETA-05C.PMD PT
Misprints and technical changes reserved
TAE Antriebstechnik
Instruction & Operating Manual
5
Copyright © by T
AE Antriebstechnik
2. Technical data
2.1 Equipment
Semi-controled single phase bridge
Acceleration/Deceleration integrator
Inner loop current regulator
Torque control
The electronic circuit is galvanically seperated from the line supply
on units with a current-transformer for armature-current detection
and tachometer control. If armature-voltage control is used the
electronic circuit is at line potential.
3. Connection of unit
(refer to Connection diagram TA-05 C chapter 8.)
2dz - 6dz
Line supply refer to Type-Marking -
230V AC 50/60Hz
2dz = Phase (L1)
6dz = MP (N, neutral)
10dz - 14dz
Armature connection
10dz = A+
14dz = A-
18dz - 16dz
Field connection
18dz = F+
16dz = F-
28d - 26d
Drive release by relay contact.
Jumper III "internal" refer to layout chapter 9.
26d - 12d
Drive release by SPS (free potential).
Jumper III "external" refer to layout chapter 9.
Dimensions
refer to drawing chapter 10
Line Voltage
230VAC - 50/60Hz
Power
0,7 kW
Armature Voltage
180V
Armature Current
max. 6 Ampere eff.
Field Voltage
210V
Field Current
max. 0,5 A
Ambient temperature
0-40°C
Speed Accuracy
with armature feedback 3%
with tachometer feedback 1%