Pikatron GmbH • division TAE Antriebstechnik • Raiffeisenstrasse 10 • D-61250 Usingen

TA-05/C

Instruction and Operation Manual

valid for art.-no.: 10091 F-TA-05/C-ISO

 

(start at modification No. 1601)

valid for art.-no.: 10092 F-TA-05/C-Sh

(start at modification No. 1601)

CAUTION:

As with any form of electrical equipment, there is always a risk involved in the handling 

of electrical machinery. The greatest care must always be exercised during installation 
and maintenance, and it is recommended that service is performed by authorized per-

sonnel only.

TA-05C.PMD PT Änd.-Nr. 00003 Stand 12.03.2012

The German text applies in cases of doubt

 

Summary of Contents for TA-05/C

Page 1: ...92 F TA 05 C Sh start at modification No 1601 CAUTION As with any form of electrical equipment there is always a risk involved in the handling of electrical machinery The greatest care must always be exercised during installation and maintenance and it is recommended that service is performed by authorized per sonnel only TA 05C PMD PT Änd Nr 00003 Stand 12 03 2012 The German text applies in cases...

Page 2: ...g a continuouse operation for 200 hours Before delivery all units are again tested for their correct functioning These extensive tests will assure that all supplied units are in perfect functional con dition If these units are installed adjusted and operated according to the instructions of this manual malfunctions are not to be expected Should despite of our preliminary tests any problems arise p...

Page 3: ...tants This symbol stands for notes and useful informations which shall make the operation easier for you Note disregard can damage or destruct the device Note disregard means a danger for the operator Table of content 1 Instructions of safety 2 1 1 Instructions and Rules 1 2 Safety 2 Technical data 3 2 1 Equipment 3 Connection of unit 3 4 Adjustments 4 5 Indicators 5 6 Functional tests and adjustm...

Page 4: ...he following stan dards DIN VDE 0100 Erection of power installations with nominal voltage up to 1000 V VDE 0113 Electrical equipment for machines VDE 0160 Electronic equipment to be used in electrical power installations VDE 0470 Part 1 Protection by frame 1 2 Safety Caution Danger Disconnect device from mains before making any repairs After the installa tion make sure that the device is properly ...

Page 5: ...uit is at line potential 3 Connection of unit refer to Connection diagram TA 05 C chapter 8 2dz 6dz Line supply refer to Type Marking 230V AC 50 60Hz 2dz Phase L1 6dz MP N neutral 10dz 14dz Armature connection 10dz A 14dz A 18dz 16dz Field connection 18dz F 16dz F 28d 26d Drive release by relay contact Jumper III internal refer to layout chapter 9 26d 12d Drive release by SPS free potential Jumper...

Page 6: ... of TAE blocking protection B 200 Nr 20003 F or B202 Nr 20163 F 4 Adjustments Minimum speed P1 Adjustment of minimum speed during operation set speed potentiometer fully counter clockwise Deceleration P2 Adjustment of the time for the linear deceleration of the rate motor from maximum to minimum speed adjustable from 2 sec to 20 sec Turning this control clockwise will decrease the deceleration tim...

Page 7: ...to be least 400 ohms 220 V connection If necessary change the polarity of the ohmmeter 5 Potentiometer P2 Deceleration time set in centre position Potentiometer P3 Acceleration time set in centre position Potentiometer P5 IxR compensation set fully counter clockwise Potentiometer P6 Stability set fully clockwise and turn back 30 Potentiometer P1 Minimum speed set fully counter clockwise 6 Switch o...

Page 8: ...0 sec otherwise dama ge to the commutator is possible 12 Acceleration time Adjust the requested acceleration time with potentiometer P3 13 Deceleration time Set speed potentiometer to 0 and adjust the requested decele ration time with potentiometer P2 Note the deceleration time cannot be less than the coasting time of the machine since the drive control operates in the first Qua drant only The dec...

Page 9: ...24V missing check supply LED 1 does not light up a Motor load is too high Drive ope rates at current limit LED 4 current limit lights up b Defective speed potentiometer c Adjustment of current limit is set too low Yellow LED 3 does not light up Output voltage does not increase when speedcontrol is turned up a I x R compensation is set too high when armature feedback control is used b Improper adju...

Page 10: ...ttent potentiometer P1 Mini mum speed b Defective speed potentiometer or connection from terminal 26z to po tentiometer a Defective power supply b Check relays and relay connections drive release c Defective speed potentiometer d Check motor and brushes e Defective fuse F1 10A FF Speed varies without change of speed potentiometer Main fuse blows Drive does not run Drive runs after control release ...

Page 11: ...TA 05 C ETA 05C PMD PT Misprints and technical changes reserved TAE Antriebstechnik Instruction Operating Manual 11 Copyright by TAE Antriebstechnik 8 Connection diagram Feld FIELD EXCITATION ...

Page 12: ...eserved TAE Antriebstechnik 12 Copyright by TAE Antriebstechnik 9 Layout Armature feedback TA 05 C ISO Art No 10091 F insulated BRI Tachometer feddback BRI BRII BRII external internal BRIII Armature feedback TA 05 C Sh Art No 10092 F with Shunt BRI Tachometer feddback BRI BRII BRII RUN ...

Page 13: ...ing circuit 33301 33503 00 Diode BY255 34221 00 SCR bridge 20 Amp L413F 34459 00 Fuse 20 x 5 super fast 10 0 A 35852 A0 Multiple plug 32pol 6 A 36360 00 Firing circuit transformer IT243 36495 C0 Current transformer CSLA1CD 58000 Q0 Transformer BV 5005 230V 10 Dimensions EMC Casing Plug in frame 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 2 p 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 EMC Casing Plu...