14
Function and Control
Function introduction for combination buttons
Child lock function
Press "+" and " -" simultaneously to turn on or turn off child lock function. When child lock function is on, " " icon is displayed
on remote controller. If you operate the remote controller, the " " icon will blink three times without sending signal to the unit.
Temperature display switchover function
Under OFF status, press "-" and "MODE" buttons simultaneously to switch temperature display between
℃
and °F.
QUIET button
Press this button to turn on or turn off the QUIET function in cool
、
heat
、
auto mode.
Note:
● Press "TURBO" or "FAN" button the unit will quit this function.
● This function is no use under fan mode or dry mode.
ECO button
In cool mode, press "ECO" button and the unit will operate under ECO mode.
Note:
● Remote controller displays " ".
● Air conditioner will operate at auto fan speed. Set temperature can’t be adjusted.
● Under cool mode, sleep function can not work with ECO mode together at the same time.
● Change mode will exit the ECO mode.
LIGHT button
Press this button can turn off the light for indoor unit’s display. " " icon on remote controller will disappear.Press this button
again to turn on the light for indoor unit’s display. " " icon on remote controller will be displayed.
The minimum cooling temperature setting
In the off mode,pressing "TEMP"and "-" button at the same time,the LCD will display the minimum cooling temperature.The
default temperature is 16
℃
and you can adjust the temperature with "+" or "-" from 16
℃
to 31
℃
. After pressing the "TEMP"
and "-" button with 3 seconds it will return to the standby mode.
In the off mode,pressing "TEMP" and "+" button at the same time,the LCD will display the maximum heating temperature.The
default temperature is 31
℃
and you can modulate the temperature with "+" or "-" from 16
℃
to 31
℃
.After pressing the "TEMP"
and "+" button with 3 seconds it will return to the standby mode.
Press the "FAN" and "MODE" 3s at the same time in heating mode,it will enter or exit the
manually
defrost.Remote controller will
display "dF" 5s,and it will show the setting temperature after 5s.
The maximum heating temperature setting
Manually defrost
Repowered within 5mins, set 16 degree under cooling mode, then press the "TURBO" button 6 times within 3s, will enter this
function.
Press the "SLEEP" and "TURBO" button 3s at the same time in heating mode,it will enter or exit defrost mode.
Timing Defrost
Collecting freon