5
Specifications
2.4 Cooling Data Sheet in Rated Frequency
Model
Rated cooling
condition(°C) (DB/WB)
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Outdoor fan
mode (rpm)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
Super High
09K
27/19
35/24
0.9~1.1
12 to 14
75 to 37
850
12K
850
18K
800
T1: Inlet and outlet pipe temperature of evaporator;
T2: Inlet and outlet pipe temperature of condenser;
P: Pressure of air pipe connecting indoor and outdoor units.
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.(Thermistor themometer)
(2) Connecting piping condition : 5m
2.5 Noise Curve
Indoor side noise when blowing
Outdoor side noise when blowing
Indoor fan motor rotating speed
Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low
Middle
High
Super High
12K
07K/09K
40
42
44
46
48
50
52
54
56
20
0
3
0
4
50
60
70
80
90
Noise dB(A)
09&12K Cooling
Indoor side noise when blowing
Outdoor side noise when blowing
Indoor fan motor rotating speed
Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low
Middle
High
Super High
18K
42
44
46
48
50
52
54
56
58
20
0
3
0
4
50
60
70
80
90
Noise dB(A)
18&24K Cooling