7.5 Installing the Outdoor Unit
•
Make sure to leave sufficient space around the unit. See figure 6-4 for minimum required
distance between the unit and nearby walls.
•
Install the unit in a location with convenient access for service and maintenance purposes.
•
Protect the unit from any heat source such as direct sun rays.
•
Prevent from any dust or strong wind installation sites.
•
Position the unit in such a way to minimize motor noise which reaches the user and
neighbors.
•
The unit must be installed at least 5 cm. above a solid surface.
•
Make sure that the unit is level.
•
Fasten the unit legs to the base. Place the rubber absorbtion cushions (supplied) under the
unit's legs to prevent vibrations.
•
For models ANL-100 and AVL-100/120/140 hanging installation is allowed. Install only
on special platform or concrete slab.
•
A drainage tube can be connected to the outdoor unit to remove condensation formed
during heating mode operation.
Fig. 7-4
Distance
Model
a mm
b mm
c mm
d mm
ANL-100
700
600
1000
200
AVL-100 700
600
1000
200
AVL-120 800
700
1000
200
AVL-140 800
700
1000
200
a
d
b
c
Summary of Contents for ANL-100
Page 15: ...SKY 15 4 1 Refrigeration Cycle ANL 100...
Page 16: ...SKY 16 4 2 Refrigeration Cycle AVL 100...
Page 17: ...SKY 17 4 3 Refrigeration Cycle AVL 120...
Page 18: ...SKY 18 4 4 Refrigeration Cycle AVL 140...
Page 47: ...SKY 47 Fig 9 2 Outdoor Unit Case Assembly 1 2 3 4 5 6 7 8 9 14 16 17 18 15 10 11 12 13...
Page 51: ...SKY 51 Fig 9 4 Outdoor Unit Electrical Components 1 2 3 4 5 6 7 8 9 10 11 12 13...
Page 53: ......
Page 54: ...EN SKY ANL AVL AVR 100 120 140 V01 R01 JAN 2005...