Installation
The operator panel is mounted on the inside of the stainless steel fascia plate using 6 M3 nuts
and washers, M4x7 clear hole spacers on the 6 M3 studs.
The fascia label is put on the front of the fascia plate using double sided adhesive.
All the connections are made using faston connectors. Blades of 0.11" are used for 12Vac
supply and sensor input. Blades of 0.25" are used for 240Vac mains, heater output and sonic
output.
The 12Vac supply is connected to CONN3 and CONN4 (12VAC) terminals on the Printed
Circuit Board (PCB).
The sensor input is connected to CONN6 and CONN7 (PRT) terminals on the PCB.
The 240Vac mains supply is connected to CONN2 (MAINS) terminal on the PCB.
The heater output is connected CONN1 (HEATER) terminal on the PCB.
The sonic output is connected CONN3 (SONIC) terminal on the PCB.