Ultra-sonic Operator Panel Instruction Manual

Technical specification

Sensor input

PRT100

Setpoint

0 to 80ºC; default to 50°C

Temperature Control

ON/OFF with 1ºC hysteresis

Temperature Output

Relay 5A max. 240Vac

Timer Control

0 to 59 minutes; default to 10 minutes

Timer Output

Relay 5A max. 240Vac

Display

Two 7-segment LED green for temperature and timer indications
6 status indicating LED; 4 green and 2 amber

Keys

5 positive feedback tactile push buttons

Connection

Faston connectors
2 for mains supply 0 to 12Vac
1 for mains input 10A max. 240Vac
1 for temperature output
1 for timer output
2 for sensor input

Supply

0-12 Vrms +/-15% 50Hz 6VA maximum

Dimensions

150mm(L) x 50mm(W) x 30mm(H)

Mounting positions

Fixing centres 140mm x 40mm; 4 x M3.5 holes

Weight

150g max.

Temperature

0 to 50 ºC operating; -20 to 65 ºC storage

Warranty

12 months return to base

UOP\IM

Page 7

19 April 1996

Issue 1.1

Summary of Contents for UOP

Page 1: ...96 Tactical Controls Limited This document contains proprietary information which is protected by copyright All rights reserved This document or parts thereof may not be reproduced in any form without...

Page 2: ...quid into which items to be cleaned are immersed The whole is caused to vibrate at 30KHz Microscopic cavitation bubbles within the fluid implode and hammer out adhered dirt from items to be cleaned Th...

Page 3: ...on six status indicating LEDs and output circuitry for temperature and timer The operator panel is mounted on the fascia plate inside the cleaning unit using six nuts and washers through six studs on...

Page 4: ...Ds are used to indicate the status of the display which includes time setting time remaining measured temperature and setpoint temperature The amber LEDs are for the status of the heater and timer out...

Page 5: ...onnectors Blades of 0 11 are used for 12Vac supply and sensor input Blades of 0 25 are used for 240Vac mains heater output and sonic output The 12Vac supply is connected to CONN3 and CONN4 12VAC termi...

Page 6: ...Tactical Controls Limited Ultra sonic Operator Panel Instruction Manual Fascia label Dimensional drawing UOP IM Page 6 19 April 1996 Issue 1 1...

Page 7: ...r temperature and timer indications 6 status indicating LED 4 green and 2 amber Keys 5 positive feedback tactile push buttons Connection Faston connectors 2 for mains supply 0 to 12Vac 1 for mains inp...

Page 8: ...g code UOP You are welcome to order the unit by code or description UOP Ultra sonic cleaning unit Operator control Panel Supplier information Tactical Controls Limited Unit 4 Marlborough Road Lancing...

Reviews: