-52-
Error Fault Description Cause
Pump Reaction / Solution
E42
Faulty LED
LED on the User Interface failure
Pump runs normally, but no display
Check ribbon able connection between the board and drive cover.
If OK, replace the drive cover
E43
Communications
failed
Loose contact
Pump runs normally. Reconnect or change the cable
E51
Motor software
protection active
IGBT transistor fault. Check motor
mechanically and electrically, check motor
electrical connections.
Check motor mechanically for external water
leaks, build up of statir condensation or
thermal damage.
Misalignmernt of the impeller eye
and volute seal ring
Pump will not run.
For misalignment, inspect the impeller area in the outlet side of the
volute. Misalignment will occur during the motor alignment process.
If OK perform a hard reset (power pump off / on)
E52
Excessive motor
temperature
Motor is too hot
Pump will not run until the motor temperature is reduced.
May require a hard reset to remove error.
Reduce ambient temperature around pump, Check for fluid
temperatures above 220˚ F. Ensure motor is installed horizontally.
Conform pump is operating within allowable Watts and
Amperage (ensure the pump is not running off it’s curve)
E53
Pump model
invalid or out
of range
Software does not match
the pump model
Pump will run, but at wrong power and speed settings.
Reflash the pump »bin« software using the HTML More Tab
hi
Pump set to
max RPM
RPM setting and application mismatch
If the pump does not change speeds as expected,
reduce speed by 100 RPM. RPM will show in place
of hi and speed modulation will occur.
Error Codes Continued