52
53
English
English
Specifications
■
Maintenance Schedule
■
How to Clean
Maintenance Schedule
* Equipment tends to degrade over time, therefore users should consider replacing the equipment every 10 years.
Periodic checks (Once a month)
Inverter Replacement
(Every 10 years)
For stubborn dirt
Hybrid Solar Inverter
Remove dust from vents and clean the front and back of the Hybrid Solar Inverter.
Remote Controller
Wipe the frame and panel with a soft piece of cloth.
ご注意
The screen is not a touch screen panel. Do not push on panel with excessive force, it damage
the panel.
NOTE
Do not use benzene, thinner or petroleum solvents to clean the Remote Controller.
Also, do not splash water on the Remote Controller.
NOTE
Moisten a soft piece of cloth with water, wring well and wipe surfaces.
1
Remove moisture from the panel by blotting the surface with a dry, soft piece of cloth.
2
Replacement
Replacement
Perform monthly checks. * Monthly checks are performed by the user.
10 Y
ears
15 Y
ears
20 Y
ears
5 Y
ears
Item
Storage Battery Input /
Output
Solar Input
The values above were measured under specified test conditions.
Rated Input / Output Voltage
86.4 V DC
Allowable input/output voltage
Operation voltage range
Number of MPP tracker input/inputs
Rated AC voltage
Rated Output Voltage
Electrical Connection
Rated Output Power
Noise Emission
Operating Temperature
Operating Humidity
Weight (Including base)
Dimensions (Including base)
≤
45 dB
-20 to +40°C (-4 to +104°F)
0 to +40°C (+32 to +104°F)
Inverter
Battery
≤
90% (Non-condensing)
Approx. 76.0 kg (168 lb)
W 680 x H 1200 x D 250 mm
(26.8 x 47.2 x 9.8 in)
(Excluding anchoring fittings)
Electrical Connection
Connection Method
Nominal AC voltage range
Rated output power
Rated power frequency
Efficiency
Power factor at rated output power
Distortion rate of the output current
240 V
120 ± 5 V AC
Single Phase 2-Wire
2.0 kVA
Single Phase 2-wire
Single Phase 3-wire
211.2 to 264 V AC
5500 W
60 Hz
Max. 92.5% (At rated output) / CEC 91.5%
≥
0.95
Combination: less than 5%, Each : less than 3%
Max. Input Voltage
Nominal Input Power per Circuit
Number of input circuit
Charge/Discharge power
Max Input / Output current
0 to 450 V DC
80 to 450 V DC
3
450 V DC
80 to 209 V DC: 580 to 2150 W
209 to 450 V DC: 2150 W ***
1 circuit
Charging: 1.5 kW, Discharging: 2.0 kW
Charging: 16.5 A, Discharging: 26.0 A
Grid Input / Output
Stand-alone Output
Specifications
*** Input power more than 2150W may be used;the DC/DC converter will limit its input power to the value stated.