33
Code switch settings
PH-G10 MC pre-amplifier (for
C10 pick-up system)
Switch position
1
2
3
4
Input impedance
(switches S51, S1)
Sensitivity
(switches S52, S2)
OFF
OFF
OFF
OFF
(
) 450 Ω ... 650 Ω (
)
> 2000 µV
OFF
OFF
OFF
ON
200 Ω ... 449 Ω
1200 µV ... 2000 µV
OFF
OFF
ON
OFF
130 Ω ... 199 Ω
800 µV ... 1200 µV
OFF
OFF
ON
ON
85 Ω ... 129 Ω
(
) 600 µV ... 800 µV (
)
OFF
ON
OFF
OFF
50 Ω ... 84 Ω
400 µV ... 600 µV
OFF
ON
OFF
ON
OFF
ON
ON
OFF
30 Ω ... 49 Ω
300 µV ... 400 µV
OFF
ON
ON
ON
ON
OFF
OFF
OFF
20 Ω ... 29 Ω
200 µV ... 300 µV
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
16 Ω ... 19 Ω
160 µV ... 200 µV
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
... 15 Ω
100 µV ... 160 µV
(
)
:= recommended settings for
C10
PH-G10 MM pre-amplifier (for
C05 pick-up system)
Switch position
1
2
3
4
Input capacitance
(switches S51, S1)
Sensitivity
(switches S52, S2)
OFF
OFF
OFF
OFF
... 120 pF
6 mV ... 10.0 mV
OFF
OFF
OFF
ON
121 pF ... 140 pF
3,5 mV ... 6,0 mV
OFF
OFF
ON
OFF
141 pF ... 160 pF
2,5 mV ... 3,5 mV
OFF
OFF
ON
ON
161 pF ... 190 pF
OFF
ON
OFF
OFF
191 pF ... 220 pF
(
) 1.5 mV ... 2.5 mV (
)
OFF
ON
OFF
ON
221 pF ... 240 pF
OFF
ON
ON
OFF
(
) 241 pF ... 260 pF (
)
OFF
ON
ON
ON
261 pF ... 290 pF
ON
OFF
OFF
OFF
291 pF ... 340 pF
1 ... 1.5 mV
ON
OFF
OFF
ON
341 pF ... 360 pF
ON
OFF
ON
OFF
361 pF ... 380 pF
ON
OFF
ON
ON
381 pF ... 400 pF
ON
ON
OFF
OFF
401 pF ... 440 pF
ON
ON
OFF
ON
441 pF ... 460 pF
ON
ON
ON
OFF
461 pF ... 480 pF
ON
ON
ON
ON
481 pF ... 500 pF
(
)
:= recommended settings for
C05
Summary of Contents for G10
Page 1: ...V 1 0 Bestellnummer Order No 9103 0311 BETRIEBSANLEITUNG USER MANUAL G 10...
Page 2: ...2...
Page 3: ...3 Seite Page Deutsch 4 English 20 Anhang Appendix Technische Daten Technical specifications 35...
Page 15: ...15...
Page 19: ...19 English...
Page 31: ...31...
Page 36: ...elektroakustik GmbH Co KG Herford Deutschland Germany...