SystemAir SYSVRF WALL 15 Q Installation Manual Download Page 3

2

installation manual 

To install properly, please read this "installation manual" at 
first. 
 
The air conditioner must be installed by qualified persons. 
 
When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible. 
 
If the air conditioner is installed on a metal part of the 
building, it must be electrically insulated according to the 
relevant standards to electrical appliances.

 

 
When all the installation work is finished, please turn on the 
power only after a thorough check. 
 
1.5kW model only can be connected to V4 Plus Series and 
Inverter Mini VRF outdoor unit

.

The outdoor unit specific 

model please contact the local dealer or technical support 
engineer. 
 
Regret for no further announcement if there is any change 
of this manual caused by product improvement. 

2.    INSTALLATION INFORMATION

INSTALLATION ORDER 

Select the location; 
 
Install the indoor unit; 
 
Install the outdoor unit; 
 
Install the connecting pipe ; 
 
Connect the drain pipe; 
 
Wiring; 
 
Test operation. 

CAUTION 

Ground the air conditioner.

 

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks. 
 

Be sure to install an earth leakage breaker.

 

Failure to install an earth leakage breaker may result in 
electric shocks.

 

 

Connect the outdoor unit wires , then connect the indoor 
unit wires.

  

You are not allow to connect the air conditioner with the 
power source until w(including  
iring and piping the air conditioner is done. 

 
While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

 

Improper drain piping may result in water leakage and 
property damage. 
 

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise. 

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise. 

 
The appliance is not intended for use by young children 
or infirm persons without supervision. 
 
Young children should be supervised to ensure that they 
do not play with the appliance

 
Don't install the air conditioner in the following locations: 
 

There is petroleum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing in 
the air (near a hot spring).

Factories where supply voltage fluctuates greatly.

In buses or cabinets.

Place like kitchen where oil permeates.

There is strong electromagnetic wave existing. 

 

There are inflammable materials or gas. 

 

There is acid or alkaline liquid evaporating. 

 

The appliance shall not be installed in the laundry. 

 

Other special conditions. 

If the refrigerant leaks during installation, ventilate the 
area immediately.

 

Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire. 
 

After completing the installation work, check that the 
refrigerant does not leak.

 

Toxic gas may be produced if the refrigerant leaks into the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker. 

Summary of Contents for SYSVRF WALL 15 Q

Page 1: ...SYSVRF WALL Wall mounted VRF indoor unit INSTALLATION MANUAL GB...

Page 2: ...tion take care not to let air substances go into refrigeration cycle Otherwise it can cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury Do not modify the leng...

Page 3: ...air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate piping in order to prevent condensation Improp...

Page 4: ...reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or noise interferences Do not install the remote...

Page 5: ...perfect The indoor unit should be installed 2 3 meters or more above the floor Installation in the following places may cause trouble If it is unavoidable please consult with the local dealer A place...

Page 6: ...nect the indoor unit first then the outdoor unit and bend and arrange the pipe carefully Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack...

Page 7: ...nose the compressor when compressor malfunction occurs 6 installation manual 6 4 Connection of the Refrigerant Pipe Connection of the refrigerant pipe should be done by professionals Double span shoul...

Page 8: ...iring cover plate Fig 7 1 faceplate the wire holder of power cord three position the wire holder of signal line five position display cover plate dial switch 2 Individually connect the power cord and...

Page 9: ...CK YELL OW To central control Monitor CCM COMM BUS To outdoor COMM BUS Please adopt the shielded twisted pair wire and connect the shielded layed to E X P Q E Y E GRAY XT1 Y G L1 L2 RED BLUE INDOOR U...

Page 10: ...g TERMAL fan is 4 minutes 01 means the time of stopping TERMAL fan is 8 minutes 10 means the time of stopping TERMAL fan is 12 minutes 11 means the time of stopping TERMAL fan is 16 minutes 1234 SW2 O...

Page 11: ...uring operation Whether the generated wind noise or condensed water by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked 8 TEST OPERATION Protection functi...

Page 12: ...SYSVRF WALL_IM EN April 2014 202000172227 MD13I 012CW...