POWER/DATA INTERFACE

 

 
The 

GSynQ 

has a 12 pin male Binder M16-423 metal shell connector mounted in 

the base. Pin outs are detailed below: 
 
Pin 

  Power 

Pin 

  Ground 

Pin 

  Ground 

Pin 

  Power 

Pin E  

 

GPS Data Out - RS422(+) 

Pin F  

 

GPS Data Out - RS422(-) 

Pin G  

 

Commands In - RS422(-) 

Pin H  

 

Commands In - RS422(+) 

Pin J  

 

1PPS Out - RS422(+) 

Pin K  

 

1PPS Out - RS422(-) 

Pin 

  Spare 

Pin M   Spare 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Straight and Right Angle mating connectors are available from Binder-USA. See 
Binder Miniature Connectors Series 423-M16 at http://www.binder-
usa.com/miniature-cylindrical-connectors/ 
 
Voltage input to the antenna may be in the range of +9 to +30 Vdc. For long cable 
lengths the input voltage must be higher in order to guarantee that at least +9V is 
available at the pins of the GSynQ connector, not at the voltage source on the 
supply end. For example, a 12Vdc (unregulated) supply is sufficient to power the 
antenna through up to approximately 75 meters of a single 24 AWG pair. If longer 
cable lengths are utilized, both power pairs should be utilized and the power supply 

Summary of Contents for GSynQ

Page 1: ...USER S GUIDE RS 422 Version 9950 Scripps Lake Drive Suite 106 San Diego CA 92196 TEL 858 566 0666 FAX 858 566 0768 Internet http www synergy gps com E Mail OEMTECH synergy gps com GSynQ MK IA Antenna ...

Page 2: ...roduct must be accompanied by a Material Return Authorization MRA number issued by Synergy Systems After obtaining an MRA number send the product transportation and insurance prepaid to Synergy Systems LLC 9950 Scripps Lake Drive Suite 106 San Diego CA 92131 USA TEL 858 566 0666 FAX 858 566 0768 GPS PERFORMANCE The Global Positioning System GPS is operated and supported by the U S Department of De...

Page 3: ...d specifically for high accuracy timing applications requiring long cable runs that are not economically feasible with expensive low loss cable and or inline amplifiers Cable lengths up to 1KM can be achieved with standard 24 AWG shielded twisted pair cable providing the user a cost effective solution to system installation General specifications are detailed below PHYSICAL CHARACTERISTICS Size 4 ...

Page 4: ...lable from Binder USA See Binder Miniature Connectors Series 423 M16 at http www binder usa com miniature cylindrical connectors Voltage input to the antenna may be in the range of 9 to 30 Vdc For long cable lengths the input voltage must be higher in order to guarantee that at least 9V is available at the pins of the GSynQ connector not at the voltage source on the supply end For example a 12Vdc ...

Page 5: ...ergy System cable If the User System does not have an RS422 input then a Synergy Systems Interface Unit can be used for interfacing to RS232 port or USB port 2 Apply power 3 Send the M12M receiver the desired initialization commands using SiRF Oncore software SynTAC or other custom software Software Windows based software to communicate with the GSynQ is available on the Synergy Systems website ww...

Page 6: ... may be made from 1 schedule 40 pipe or any tubing or conduit with an outside diameter of 1 5 or less In order to mount the antenna on the end of a 3 4 NPT threaded pipe or 1 14 Marine Thread the user should order a Synergy P N 10001511 1 mounting adapter This will provide a step down between the 28mm thread on the antenna and the pipe thread If the antenna is being mounted on a smooth 1 OD pipe o...

Page 7: ...ed by obtaining the radiation patterns of the transmitting antennas and installing the GSynQ where signal strength is at a minimum The Antenna is designed to filter out unwanted frequencies however it is still prudent to install the GSynQ as far away as possible from transmitting antennas This will minimize the effects of possible harmonics that may be within the pass band of the M12M and Antenna ...