Both 10001511 adapters are made from anodized aluminum for excellent
performance in environmentally hostile installations.
Synergy Systems, LLC supplies Extension Cables for any length up to 1 kilometer.
Bulkhead connectors are also available. When requesting a quote, please indicate
whether the cable must be UV tolerant for outdoor use or fire retardant for indoor
cable runs.
For Long-term, watertight integrity the interface between the Binder connector at the
base of the GSynQ Antenna and that of the connector on the interface cable should
be protected with a length of dual-wall shrink tubing. The adhesive on the inside of
the tubing will provide a water-tight seal for the connector interface.
Most GSynQ installations require the antenna be co-located with a cellular base
station or other high power transmitter. A careful installation will place the GSynQ in
an area with minimum RF field strength. This can be accomplished by obtaining the
radiation patterns of the transmitting antennas and installing the GSynQ where
signal strength is at a minimum. The Antenna is designed to filter out unwanted
frequencies, however it is still prudent to install the GSynQ as far away as possible
from transmitting antennas. This will minimize the effects of possible harmonics that
may be within the pass-band of the M12M and Antenna modules.
Several industry standards exist for lightning protection which is not addressed in
this User’s guide. However, it is recommended that the GSynQ be installed in an
area so that it is not at the highest point, and so that any lightning rods are well
above the antenna itself. Although it is not possible for the GSynQ to survive a direct
strike, it is possible for the GSynQ to survive the secondary effects of lightning due
to the internal 600W transient suppressors on each of the interface wires.
Support
If you have any problems at all, please do not hesitate to contact Synergy’s technical
support team, either by the phone number on the front of this document, or by email
at: [email protected]
10001500D Jan 28 2011