Stand-Alone Terminals
Set-up mode
Define Duress code
Code 53-->
0000-9999
Enables defining what will be the duress code
Card parameters
Refer to how the proximity track will be read:
Reset alarm
In set-up mode, after keying-in code 51, key-in 4 to shut-off the alarm.
2 digits
Start position (01-37) Card number offset
2 digits
Length (01-06)
Card number length
2 digits
Total characters
Number of digits on card (when defining 00 -
doesn’t check card length- accepts all card
lengths upto 6)