Stand-Alone Terminals
Set-up mode
code (four digit code – used by all card-holders).
Card and PIN Code – Control is performed by Card and a personal four digit
code. This mode is the most secure.(4 digit code – used by each card-holder).
3.2
General definitions
Open Door
Access can be given by using a Master Code. After entering “Programming
Mode,” enter “0”.
Open Door Time
It is possible to adjust the “window” of accessibility during which a door
opens when accessed. To change the accessibility time, after entering the
“Programming Mode,” enter “10” and then three digits. For example if you
enter 015, the accessibility time is 1.5 seconds.
Set Global Code
You can change a Global Code by way of “Instruction Code” – 15. After
entering “Programming Mode” enter “15” and afterward a four digit number
that will be the new Global Code.
Set New Master Code
The Master Code can be change by way of “Instruction Code” – 13. After
entering “Programming Mode” enter “13” followed by a eight digit number
that will serve as a new master Code.
Note: It is recommended to change master code when setting up.
Erase All
Warning:
!
Cards can not be restored after erased!
SY-11
After entering the “Programming Mode,” enter “60” and then
eight digits Master code.
After entering the “Programming Mode,” enter “62” to Erase all.
PRX-40/A
After entering the “Programming Mode,” enter “60” to Erase All
After entering the “Programming Mode,” enter “61” to initialize
memory
Note: Before starting teaching modes such as: 21,22,23 etc., it