Synapius ECS 20 Series User And Installation Manual Download Page 14

Clear ing all the user pin codes

The user pin codes from 1 to 99 can be cleared in a single procedure.
Follow the next procedure to perform this.

Press CE to clear existing keystrokes

xxxxxxxx

enter the master code

now, the red LED goes on, which means the device is in programming mode

00000000 enter eight zero’s

Confirm clearing the user codes otherwise press 

 to cancel

Clearing the user codes takes a little time thus wait until the green LED turns off before proceeding.

Clear ing a sin gle user
To clear a single user position and the corresponding pincode you must store 00000000 (eight zero’s)
as user pincode. This will replace the user ID number with blank. For this reason a user pincode
consisting of eight zero’s is a non valid pincode for normal usage. 

Read ing the number of E- stops of an in di vid ual user

If the E-stop handling function 2 is active (re-start by the user code) the number of E-stops are
recorded for each individual user. This number of E-stops can be read out. To do this follow the next
procedure.

To clear existing keystrokes

xx

 

user number (2 digits)

The Red and green LED’s flashes to indicate the number of E-stops.

The red flashes the ten’s and the green flashes the one’s. Also, multiplying the red flashes by ten and
then adding the number of green flashes gives the total of E-stops.
For example: If a user caused 23 E-stops, reading out results in two red flashes and three green flashes.
To clear the E-stop counter, for a user xx, just reprogram the user pincode at the same user xx place.
This might be the same or a new pincode.

Note:
Although the user numbers 98 and 99 are valid user numbers, the recording of E-stops is not applicable 
to this two user numbers for this numbers are reserved for reading the two last users.

 

Electronic Code Switches

Summary of Contents for ECS 20 Series

Page 1: ...Electronic Code Switch User and installation manual ECS 20xx series Last update January 20 2009...

Page 2: ...Copyright TMPhysics 2006 All right reserved by Synapius BV The Netherlands Electronic Code Switches...

Page 3: ...Electronic Code Switches...

Page 4: ...ay 16 Programming the automatic turn off delay 16 Disabling the automatic turnoff 16 Configuring the device for access control 17 Setting the polarity of the safety switch input signal 18 Emergency st...

Page 5: ...ompatibility with the former models 29 Mechanical 29 Electrical 29 Operation of the ECS 29 New features 30 APPENDIX A 32 Configuration list 32 CODE LIST 33 Appendix B wiring 37 Electronic Code Switche...

Page 6: ...Electronic Code Switches...

Page 7: ...Industrial version kgklj Electronic Code Switches...

Page 8: ...useful during maintenance of the installation For advanced engine control it is possible to connect the ECS to the SYNAPS12 24 to control more device or switch specific operating levels This last avo...

Page 9: ...Electrical Wide power supply versions 12 to 24 VDC or 12 24 VAC and 48 90VDC see ordering codes for powersupply ranges Power supply current is less then 60 mA Electronic Code Switches...

Page 10: ...The ON OFF switch toggles the installation on or off by each tapping on the ON OFF button The status of the sense input of the emergency stop is shown by the red led If the installation is turned on...

Page 11: ...nd maximum 8 digits The pincode 00000000 8 zero s is reserved for clearing an existing pincode so that this is not a valid pincode The User ID is used in the following cases Entering a new user pincod...

Page 12: ...n which means the device is in programming mode 00 this is the location of the master code xxxxxxxx Now enter your new personal master code min 4 max 8 digits Write down this code see code list append...

Page 13: ...on which means the device is in programming mode xx enter the location user ID number always 2 digits xxxxxxxx Now enter your new personal master code min 4 max 8 digits Write down this code see code...

Page 14: ...ops of an individual user If the E stop handling function 2 is active re start by the user code the number of E stops are recorded for each individual user This number of E stops can be read out To do...

Page 15: ...Electronic Code Switches...

Page 16: ...wire can be connected through an unused contact on the accelerator Programming the automatic turn off delay Note for normal use not for access control the access control register must be set to zero T...

Page 17: ...en 60 the this number is treated as hold time in seconds If a number greater then 60 is entered then the current number of minutes in the turnoff delay is used as hold time The grey wire is used in th...

Page 18: ...s not zero If the ECS is turned off and the turnoff delay is not zero it is not possible to start the engine as long as the safety switch is not closed If the safety switch is a seat switch on a verhi...

Page 19: ...start the engine The ECS provides three programmable E stop functions which will determine what to do after an emergency stop E stop E stop code 0 No action The signal will be ignored E stop code 1 Im...

Page 20: ...as follows To clear existing keystrokes xxxxxxxx enter the master code The red LED goes on to indicate the program mode 03xx where xx are the minutes for dead time after an E stop E g if a dead time o...

Page 21: ...you can later if nesessary restore you application settings To clear existing keystrokes xxxxxxxx enter the master code The red LED goes on to indicate the program mode 0600 Set the current configura...

Page 22: ...e before the last user The red and green LED s will flash now the user The red flashes the ten s and the green flashes the one s Also multiplying the red flashes by ten and then adding the number of g...

Page 23: ...porarily follow the next instructions To clear existing keystrokes xxxxxxxx enter the master code To set in program mode 3 code 3 to set out of operation Confirm To indicate that the machine is out of...

Page 24: ...ergency signal occurs the E stop procedure mode 2 is active That means that restarting must be evoked by the master code followed by the desired E stop mode 0 1 or 2 To return to normal mode follow th...

Page 25: ...rocedure To clear existing keystrokes xxxxxxxx Enter the PUC code Use the CE button to avoid confusion with possible user pin codes xxxxxxxx enter again the PUC code Use the CE button to avoid confusi...

Page 26: ...9 Installation Electronic Code Switches...

Page 27: ...ecretary For bigger loads an external relay must be used Power consumption 10mA when relay not activated and less then 60mA in activated operation Casing ABS plastic Weatherproof front side IP65 Rear...

Page 28: ...1 Ordering Information TMP order Numbers TMP order number ECS2024 ECS2090 Notes C 40o to 60o C S 10o to 60o C P Plastic casing A Aluminium casing T surface mount F panel mount Electronic Code Switches...

Page 29: ...itch at the back of the old model is not present any more on the new device This was one of the major source of possible problems Instead of the dip switch the code switches are separate available for...

Page 30: ...Reverse polarity input grey wire NO YES Start inhibit Auto turnoff time 0 NO YES Out of operation NO YES Service and maintenance mode NO YES Anti condense and ice Cold climate version NO optional But...

Page 31: ...Electronic Code Switches...

Page 32: ...e Supplier Parameter Factory setting User application setting Master code 0000 Auto turnoff delay time 5 minutes Acces mode 0 seconds Safety sense Active low Shock detection limit 50 Emergency stop de...

Page 33: ...ID PUC Activation code ECS serial Date of purchase Supplier User ID pincode User name Operating level 00 Master code 9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Electron...

Page 34: ...User ID pincode User name Operating level 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Electronic Code Switches...

Page 35: ...User ID pincode User name Operating level 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Electronic Code Switches...

Page 36: ...User ID pincode User name Operating level 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Electronic Code Switches...

Page 37: ...sis If the automatic switch off is not used leave the grey wire unconnected or to the blue wire The white wire can be connected to optional devices like Emergency switches Engine control switches e g...

Reviews: