![Symmetron Stylitis-10 Installation Manual Download Page 29](http://html.mh-extra.com/html/symmetron/stylitis-10/stylitis-10_installation-manual_1419649029.webp)
STYLITIS-10 INSTALLATION GUIDE [0516]
29
SELECTION
IN THE
‘MEASURE’
LINE
SELECTION
IN THE
‘SENSOR’
LINE
MANUFACTURER
Wire at
+BAT Ext
pin
Wire at
ANALOG pin
(eg [CH2])
Wire at [GND]
pin
‘Solar
Radiation
Global’ ή
‘Solar
Radiation
Diffused’ ή
‘Solar
Radiation
Direct beam’
CMP3
Kipp & Zonen
-
Red or White
Blue or Black
+Shield
CMP6
Kipp & Zonen
-
Red
Blue +Shield
CMP11
Kipp & Zonen
-
Red
Blue +Shield
SP-110
Apogee
-
Red
Black+ White
SP-212
Apogee
White
Green
Clear
SP-215
Apogee
White
Green
Clear
NOTES:
The first three sensors can be used with an amplifier, as well, as you can see in the
diagram above.
The SP-110 does not require a signal amplification, because its output signal is of around
a few hundred mV. Therefore, do not use the connection on the right.
The SP-212 and SP-215 are amplified pyranometers, so that they can output a 0~2.5V or
a 0~5V signal, therefore they need power supply (5~24V)
The Slope, Offset are automatically updated, but for calibrated sensors, you can change
them in retrospect.
14.
OTHER USED ANALOG SENSORS
CONNECTION AND SETUP:
SELECTION
IN THE
‘MEASURE’
LINE
SELECTION IN
THE ‘SENSOR’
LINE
MANUFA-
CTURER
[+BAT
Ext]
Analog
pin (eg
[CH2])
[GND]
Humidity
External
YGRO
SYMMETRON
Red Wire
White
Wire
Black Wire
Humidity
External
THYGRO
(humidity sensor)
SYMMETRON
Red Wire
White
Wire
Black Wire
Temperature
External
110S
NRG
Red Wire
White
Wire
Black Wire
Barometric
Pressure
External
BARON
SYMMETRON
Red Wire
White
Wire
Black Wire
Barometric
Pressure
External
PTB100A/PTB10
0B/
PTB101B/PTB10
1C
Vaisala
SUPPLY
pin
VOUT pin
GND +
AGND pins
Barometric
Pressure
External
PTB2102/PTB21
03
Vaisala
Pink Wire
White
Wire
Blue + Brown
Wire
Barometric
Pressure
External
CS105
Vaisala
Red
Wire@
SUPPLY
pin
Blue Wire
@VOUT
pin
Black Wire
@GND pin +
Yellow Wire
@AGND pin