STYLITIS-10 INSTALLATION GUIDE [0516]
11
SETUP:
Click ’Read Inputs Setup’ in the ‘Setup’ tab, in the ‘Data logger online’ bar on the left
Open CH1’s or CH8’s node.
.
Click the MEASURE line and select
‘Wind Speed Horizontal’.
Click the SENSOR line and select
‘A100K’, ‘A100LM’ or ‘A100L2FreqOut’.
The channel type (first line), along with the Slope, Offset are automatically updated.
You can also change the units by clicking the UNITS line. The Slope and Offset are
automatically updated again.
In order to save the changes, click
‘Write Setup’ in the ‘Setup’ tab, in the ‘Data logger
online’ bar on the left. If you wish to change the setup of multiple channels, one
‘Write Setup’ in the end is enough.
ΝΟΤΕ: For calibrated anemometers you can enter the correct SLOPE και OFFSET
values in retrospect.
Connect serially via Opton 4. (Connect the
computer’s COM port to the datalogger’s
PERIPHERAL port).
Before changing the setup select:
ACQ OFF
.
After changing setup select:
ACQ ON
to start acquisition (data logging).