Chapter 4 Command Listing and Status Information
Status Information
4-16
User’s Guide
Powerup Status Register Bit Assignments
P
= Positive Transition
N
= Negative Transition
E
= Enable
A
= Alarm LED
Holdover Status Register Bit Assignments
P
= Positive Transition
N
= Negative Transition
E
= Enable
A
= Alarm LED
Bit
Information Reported
Comments
P
N
E
A
0
First satellite tracked
Condition = 1 when first satellite becomes
tracked following powerup.
1
0
1
0
1
Oscillator oven warmed up
This bit sets when the internal oscillator has
warmed up following powerup.
1
0
1
0
2
Date & Time Valid
This bit sets when first lock is attained after
powerup.
1
0
1
0
Bit
Information Reported
Comments
P
N
E
A
0
Holding
Condition = 1 if in holdover and holding.
1
0
0
0
1
Waiting
Condition = 1 if in holdover and waiting to
recover.
1
0
0
0
2
Recovering
Condition = 1 if in holdover and recovering.
1
0
0
0
3
User-specified threshold
exceeded
Condition = 1 if in holdover longer than value
set by :ROSC:HOLD:DUR:THReshold.
1
0
1
1
Summary of Contents for Z3801A
Page 6: ...Contents vi User Guide ...
Page 12: ...In This Guide xii User Guide ...
Page 13: ...1 Getting Started ...
Page 30: ...Chapter 1 Getting Started Using Commands to Control Key Functions Examples 1 18 User Guide ...
Page 31: ...2 Features and Functions ...
Page 44: ...Chapter 2 Features and Functions In Case of a Problem 2 14 User Guide ...
Page 45: ...3 Using the Receiver Status Screen ...
Page 63: ...Chapter 3 Using the Receiver Status Screen Receiver Status Screen Data User Guide 3 19 ...
Page 67: ...4 Command Listing and Status Information ...
Page 90: ...Chapter 4 Command Listing and Status Information Error Messages 4 24 User s Guide ...
Page 91: ...5 Specifications Summary ...
Page 98: ...Index Index 4 User Guide wiring dc power input 1 5 ...