Chapter 4 Command Listing and Status Information
Status Information
User’s Guide
4-15
Questionable Status Register Bit Assignments
P
= Positive Transition
N
= Negative Transition
E
= Enable
A
= Alarm LED
Operation Status Register Bit Assignments
P
= Positive Transition
N
= Negative Transition
E
= Enable
A
= Alarm LED
Bit
Information Reported
Comments
P
N
E
A
0
Time has been set. Event only
This could occur after an extensive holdover
period. When GPS is re-acquired, if receiver
time differs from GPS time, this bit will be set.
_
_
1
1
1
User-reported
____
0
0
0
0
Bit
Information Reported
Comments
P
N
E
A
0
Powerup operation summary
Summary of powerup status register
1
0
0
0
1
Locked operation
Condition = 1 if locked to GPS, 0 otherwise.
1
0
0
0
2
Holdover operation summary
Summary of holdover status register.
1
0
1
1
3
Position hold operation
Condition = 1 if in position-hold mode, 0 if in
survey mode.
1
0
0
0
4
Sufficient satellites to allow
lock to GPS
Condition = 1 indicates current satellite
tracking allows for locking.
1
0
0
0
5
Hardware status summary
Summary of hardware status register.
1
0
1
1
6
Log almost full
Condition = 1 indicates that the diagnostic log
is nearly full (you may want to read and clear it)
1
0
0
0
Summary of Contents for Z3801A
Page 6: ...Contents vi User Guide ...
Page 12: ...In This Guide xii User Guide ...
Page 13: ...1 Getting Started ...
Page 30: ...Chapter 1 Getting Started Using Commands to Control Key Functions Examples 1 18 User Guide ...
Page 31: ...2 Features and Functions ...
Page 44: ...Chapter 2 Features and Functions In Case of a Problem 2 14 User Guide ...
Page 45: ...3 Using the Receiver Status Screen ...
Page 63: ...Chapter 3 Using the Receiver Status Screen Receiver Status Screen Data User Guide 3 19 ...
Page 67: ...4 Command Listing and Status Information ...
Page 90: ...Chapter 4 Command Listing and Status Information Error Messages 4 24 User s Guide ...
Page 91: ...5 Specifications Summary ...
Page 98: ...Index Index 4 User Guide wiring dc power input 1 5 ...