Test 1: +7 dBm Input Level
1
Apply power to the 58502A and observe successful completion of
self-test.
2
Set the signal generator to:
FREQUENCY: 10 MHz
LEVEL: +7 dBm
3
Connect the signal generator output to the 58502A input
A
or
B
rear-
panel input connector as shown in Figure 2-6.
4
Connect the RMS voltmeter via the 50
Ω
load to the 58502A Output 1
as shown in Figure 2-6.
Figure 2-6. Input Level Response Test Setup
5
Set the RMS voltmeter to 3V Full Scale Range.
6
Starting with Output 1, verify that the RMS voltage on each of the
twelve Outputs is from 0.707 to 1.12 Vrms.
7
Record the reading of each output channel on the Performance Tests
portion of the 58502A Performance Test Record in the Test 1 section,
located on page 2-14.
HP 3400B
RMS Voltmeter
or equivalent
50
Ω
Feedthrough
(HP 10100C)
BNC Cable
BNC
Cable
HP 8663A
Synthesized Signal Generator
or equivalent
Output
Outputs
1 - 12
N-to-BNC
Connector
(1250-0780)
Input
A or B
A
B
1
2
3
4
5
6
7
8
9
10
11
12
5 VRMS MAX
100-240 VAC 50/60GHz
40 VA Max
!
!
!
58502A
Distribution
Amplifier
Summary of Contents for 58502A
Page 10: ...In This Guide x User s Guide ...
Page 11: ...1 Getting Started ...
Page 27: ...2 Performance Tests Verifying Specifications ...
Page 29: ...Chapter 2 Performance Tests Introduction User s Guide 2 3 ...
Page 47: ...3 Features and Functions ...
Page 59: ...4 Command Reference ...
Page 73: ...5 Functional Description ...
Page 78: ...Chapter 5 Functional Description Functional Block Description of the 58502A 5 6 User s Guide ...
Page 79: ...6 Service ...
Page 81: ...7 Specifications ...
Page 84: ...Chapter 7 Specifications Introduction 7 4 User s Guide ...