2-6-2
PZ3PDMCK
Adjusting procedure
1. Get Pattern to be Full White.
2. Check the waveform using Oscilloscope
1) Triggering through V_TOGG of LOGIC Board.
2) Connect the OUT240 Test Point at the center of Y_buffer to other channel, and then check the 1st SF
operating waveform of 1TV-Field.
3) Check the waveform as before by adjusting Horizontal Division.
4) Check the Reset waveform when the V_TOGG Level is changed.
Set the Rising Ramp like upper picture by adjusting VR5001.
5) Set the Falling Ramp like upper picture by adjusting VR5002.
VR5002
Adjustment : Falling Ramp
Oscilloscope Setting : 50V / 40us
VR5001
Adjustment : Rising Ramp
Oscilloscope Setting : 50V / 40us