2-6-1
PZ3PDMCK
OPERATION CHECK
Adjustment Specification, Checking Position etc.
W1 Ramp Waveform Inclination Adjustment (Y-Board)
1
st
Sub Field
Adjust VR5001 to set the time of Yrr
(Main Reset Rising Ramp) like the
below picture.
Oscilloscope Setting :
50V / 40us
Adjust VR5002 to set the time of Yfr
(Main Reset Falling Ramp) like the
below pict
ure.
Oscilloscope Setting :
50V / 40us
< Falling Ramp > <Rising Ramp>
4 block
2 block
1 block
7 block