2-3-15
PZ3PDMOP
Defect: Sustain (horizontal stripe) Short
Defect: Dielectric material layer damage
–
Symptom:
Combined or adjacent lines are short in
sustain direction. The line appear brighter than
other at Ramp gradation pattern or low gradation
patter
–
Cause:
1)
Manufacturing:
Panel electrode short/ Foreign
material.
2)
Parts:
Board/ connector/ pin error
3)
Operation:
connector/ assembling error
–
Symptom:
Burn caused by the damage of address
bus dielectric layer appears in the panel discharge/
non discharge area. sustain also open/short occurs
by the damage of address sustain printout
<Add Block and Line Open>
<Add and Sustain Open>
–
Cause:
layer uneven/ abnormal voltage/ foreign
material repair failed