1-2-4
L0604IMP
Safety Check after Servicing
Examine the area surrounding the repaired location
for damage or deterioration. Observe that screws,
parts and wires have been returned to original posi-
tions. Afterwards, perform the following tests and con-
firm the specified values in order to verify compliance
with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)
Table 1 : Ratings for selected area
Note: This table is unofficial and for reference only. Be
sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current be-
tween B (any two parts or contacts, between any part
or contact and either pole of the power cord plug
prongs) and externally exposed accessible parts (RF
terminals, antenna terminals, video and audio input
and output terminals, microphone jacks, earphone
jacks, etc.) is lower than or equal to the specified val-
ue in the table below.
Measuring Method: (Power ON)
Insert load Z between B (any two parts or contacts,
between any part or contact and either pole of the
power cord plug prongs) and exposed accessible
parts. Use an AC voltmeter to measure across both
terminals of load Z. See Fig. 2 and following table.
Table 2: Leakage current ratings for selected areas
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
AC Line Voltage
Region
Clearance
Distance (d) (d')
110 to 130 V
USA or
CANADA
≥
3.2 mm
(0.126 inches)
Chassis or Secondary Conductor
d
d'
Primary Circuit Terminals
Fig. 1
AC Voltmeter
(High Impedance)
Exposed Accessible Metal Part
B
One of Power Cord
Plug Prongs
Z
1.5k
Ω
0.15
µ
F
Fig. 2
AC Line Voltage
Region
Load Z
Leakage Current (i)
Earth Ground (B) to:
110 to 130 V
USA
0.15µF CAP. & 1.5k
Ω
RES. connected in
parallel
i
≤
0.75mA peaks
Exposed accessible
parts
Summary of Contents for 6842PE M
Page 5: ...1 1 2 L0604SP DIMENSIONS 330 600 70 71 6 660 532 8 1054 934 9 115 58 57...
Page 48: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01011 1...
Page 49: ...1 9 23 1 9 24 Jack CBA Top View Jack CBA Bottom View BL0600F01011 2...
Page 50: ...Switch CBA Top View Switch CBA Bottom View 1 9 25 1 9 26 BL0600G04011 2...
Page 53: ...TP2022 WF4 TP2023 WF5 Digital CBA Bottom View 1 9 31 1 9 32 BL0600G04011 1...
Page 82: ...6842PE L0604UE 2004 09 21...