2-1-7
L0604DCP
(3) XM
(4) LM
1. Disconnect connectors CN4001 and CN4002.
2. Remove all flat cables.
Note: Refer to “2. Signal Connectors of Boards” section on page
2-1-2.
3. Unscrew all screws of XM and remove it.
Caution:
1. The connection of FFC connectors must be completely aligned
and locked tightly. Miss-alignment of connector and Flat Cable
may cause hard fail of module.
2. All connectors should be kept clean with no dust. Any conductive
foreign particle may cause hard failure of module. Remove dust by
using clean air is highly recommended before connection is made.
XM
CN4001
CN4002
Flat cables
LM
CN201
CN401
CN402
CN403
CN803
LA03
CN101
1. Disconnect all connectors of CN101, CN201, CN401,
CN402, CN403, CN803, and LA03.
2. Unscrew all screws of LM and remove it.
Caution:
1. The Connection of FFC connectors must be completely
aligned and locked tightly. Mis-alignment of connector
and Flat Cable may cause hard failure of module.
2. All connectors should be kept clean with no dust. Any
conductive foreign particle may cause hard failure of
module. Remove dust by using clean air is highly rec-
ommended before connection is made.
Summary of Contents for 6842PE M
Page 5: ...1 1 2 L0604SP DIMENSIONS 330 600 70 71 6 660 532 8 1054 934 9 115 58 57...
Page 48: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01011 1...
Page 49: ...1 9 23 1 9 24 Jack CBA Top View Jack CBA Bottom View BL0600F01011 2...
Page 50: ...Switch CBA Top View Switch CBA Bottom View 1 9 25 1 9 26 BL0600G04011 2...
Page 53: ...TP2022 WF4 TP2023 WF5 Digital CBA Bottom View 1 9 31 1 9 32 BL0600G04011 1...
Page 82: ...6842PE L0604UE 2004 09 21...