2-1-2
L0604DCP
2. Signal Connectors of Boards
No.
Name of Cable
Connection
Disconnecting Note
Connecting Note
F1 FPC (Flexible Printed Circuit)
Panel -YBU, L
1
2
F2
Flat Cable
Panel - XM
3
4
F3
FFC (Flexible Flat Cable)
LM-YM
-
-
F4
FFC (Flexible Flat Cable)
LM-XM
-
-
F5
FFC (Flexible Flat Cable)
LM-LBE
-
-
F6
FFC (Flexible Flat Cable)
LM-LBF
-
-
F7
FFC (Flexible Flat Cable)
LM-LBG
-
-
F1
F3 F5
F6
F7
F4
F2
NOTES:
1. Pull out with two hands from both sides of plastic plate.
2. Push with same pressure at both sides until completely inserted.
Caution: Please be cautious that the pins of connector of FPC do not bend by miss-aligning of male
and female connectors.
3. Perform the following procedures for disconnection.
a) Pull out the locker of connector as shown right.
b) Push down the Flat Cable slightly and take back the Flat Cable (F2).
4. Perform the following procedures for connection.
a) Push down the Flat Cable slightly and insert to the slot of connector.
b) Lock the locker until a “tick” sounds.
Locker
Locker
Flat Cable (F2)
Connector of
Flat Cable (F2)
Summary of Contents for 6842PE M
Page 5: ...1 1 2 L0604SP DIMENSIONS 330 600 70 71 6 660 532 8 1054 934 9 115 58 57...
Page 48: ...1 9 21 Analog CBA Bottom View 1 9 22 BL0600F01011 1...
Page 49: ...1 9 23 1 9 24 Jack CBA Top View Jack CBA Bottom View BL0600F01011 2...
Page 50: ...Switch CBA Top View Switch CBA Bottom View 1 9 25 1 9 26 BL0600G04011 2...
Page 53: ...TP2022 WF4 TP2023 WF5 Digital CBA Bottom View 1 9 31 1 9 32 BL0600G04011 1...
Page 82: ...6842PE L0604UE 2004 09 21...