4.4 Using the appliance
The first commissioning of the appliance must be carried out by qualified
personnel.
The following checks and operations must be carried out:
- check that the fuel shut-off and water taps of the water system are open
Fig. 2
- insert the batteries supplied in the battery compartment (Fig. 16)
- the water heater powers on and the display shows: the type of gas, the
size, the type of ignition and the software version, and then the current
operating temperature
- if the appliance does not power on, press button B (ON/OFF) or check
the battery charge
When there is a request for water, the automatic ignition devices turns
on the pilot flame. Once the flame has been detected, the main burner
switches on and the pilot flame switches off.
- during the request, the instant water temperature is shown on the dis-
play
- at the end of the water request (when the tap is turned off), the main
burner and the display switch off and the appliance goes into standby,
ready for a new request
Domestic hot water pick-up
- Open a domestic hot water tap. The temperature of the domestic hot
water dispensed is shown on the display (rounded up to the nearest
degree).
- The burner comes one, when the flame is detected, the corresponding
symbol is shown on the display.
- The appliance produces domestic hot water at the temperature set.
- When the water tap is shut-off, the boiler switches off and prepares for
the next start-up.
36
Fig. 3
4.4.1 Changing the DHW setpoint
Pressing the "+" or "-" key it is possible to change the setpoint for the
domestic hot water. With the "+" key the value increases, with the "-" key
it decreases.
Press and hold the + or - button to increase or decrease the value quickly.
39
Fig. 4
If there is a fault the water heater carries out a “STOP” (see section Op-
erating faults and reset).
4.5 Operating faults and reset
In the event of a fault, the displays summarised and described in the table
are shown.
Error type
Transitory
Definitive
Error
code
Ignition failure
Transitory
E1
Ignition failed
Transitory
E2
Electronic fault alarm
Transitory
E3
DHW NTC sensor fault alarm
Transitory
E4
parasite flame fault
Transitory
E6
Flue/limit thermostat alarm
Definitive
E7
Over temperature alarm
Transitory
E8
Maximum operating time exceed-
ed
Transitory
E9
Communication lost between
display and control board
Transitory
EE
In the event of a transitory fault the appliance independently attempts a
reset of operations.
b
If a temporary alarm shows 5 times in the space of 15 minutes it
becomes definitive.
Fig. 5
Where there is a definitive alarm, to restore normal appliance operation
press the RESET button and hold for 5 seconds.
If the problem persists, contact the technical support service.
When a definitive fault appears on the display, the error code alternates
with the message “nL”.