j) Setting the activation duration for output or toggle operation
The potential-free changeover contact of the code lock can be activated via a user
transponder or a user fingerprint.
The following functions are possible:
•
Changeover contact is activated for 2....99 seconds (5 seconds by default); optimal e.g.
for a door opener
•
Changeover contact is activated for 100 ms (pulsed operation); optimal e.g. for controlling
an alarm system
•
Toggle operation; the changeover contact toggles between the two switching positions
for each valid access attempt; optimal e.g. for activation/deactivation of an alarm system
Proceed as follows:
•
The code lock must be in standby mode; the control LED lights up red.
• Activate programming mode, as described in chapter 10. b); then the control LED will flash
red. Example:
•
Press the button. The control LED will light up orange.
•
Enter the desired time/function: ....
= Toggle operation, output is switched
= Pulsed operation, output is activated for 100 ms
.... = Output is activated for 2...99 seconds
•
Press the
button to confirm your entry. The control LED briefly lights up green and then
flashes red (programming mode).
•
To exit programming mode, press the button. The control LED now glows red steadily,
and the code lock is in standby mode.
44