Diagnostics
5
STEP 1-DA
– Press
and
simultaneously for 3 seconds. If screen in Step 2-DA does
not appear in 5 seconds, the lock on the valve is activated. To unlock, press
, NEXT,
,
and SET CLOCK in sequence, then press NEXT and
simultaneously for 3 seconds.
STEP 2-DA
–
Days, since last regeneration:
This display shows the days since the
last regeneration occurred. Press NEXT to go to Step 3-DA. Press REGEN to exit
Diagnostics.
STEP 3-DA
–
Gallons, since last regeneration:
This display shows the number of
gallons that have been treated since the last regeneration. This display will equal 0
(zero) if a water meter is not installed. Press the NEXT to go to Step 4-DA. Press
REGEN to return to the previous step.
STEP 4-DA
–
Gallons, reserve capacity used for last 7 days:
If the valve is set up as
a softener, a meter is installed, and Set Gallons
Capacity is set to “AUTO,” this display shows 0 day (for
today) and flashes the reserve capacity. Pressing the
button will show day 1 (which would be yesterday)
and flashes the reserve capacity used. Pressing the
button again will show day 2 (the day before yesterday)
and the reserve capacity. Keep pressing the
button
to show the gallons for days 3, 4, 5, and 6. The
button can be pressed to move backwards in the day
series. Press NEXT at any time to go to Step 5-DA.
Press REGEN to return to the previous step.
STEP 5-DA
–
Gallons, 63 day usage history:
This display shows day 1 (for yesterday)
and flashes the number of gallons treated yesterday. Pressing the
button will show
day 2 (which would be the day before yesterday) and flashes the number of gallons
treated on that day. Continue to press the
button to show the maximum number of
gallons treated for the last 63 days. This display will show dashes if a water meter is
not installed. Press NEXT at any time to go to Step 6-DA. Press REGEN to return to
the previous step.
STEP 6-DA
–
Flow Rate, current:
Turn the water on at one or more taps in the building.
The flow rate in gallons per minute will be displayed. If flow stops, the value will fall to 0
(zero) in a few seconds. This display will equal 0 (zero) if a water meter is not installed.
Press NEXT to go to Step 7-DA. Press REGEN to return to the previous step.
STEP 7-DA
–
Flow Rate, maximum last seven days:
The maximum flow rate in
gallons per minute that occurred in the last seven days will be displayed. This display
will equal 0 (zero) if a water meter is not installed. Press NEXT to go to Step 8-DA.
Press REGEN to return to the previous step.
STEP 8-DA
–
Gallons, total used since last reset:
The total number of gallons used
since last reset will be displayed. This display will equal 0 (zero) if a water meter is not
installed. Press NEXT to go to Step 9-DA. Press REGEN to return to the previous step.
STEP 9-DA
–
Days, total number since last reset:
The total number of days the
control valve has been in service since last reset will be displayed. Press NEXT to go
to Step 10-DA. Press REGEN to return to the previous step.
STEP 10-DA
–
Regenerations, total number since last reset:
The total number of
regenerations that have occurred since last reset will be displayed. Press NEXT to
exit Diagnostics. Press REGEN to return to the previous step.
Step 1-DA
Step 2-DA
Step 3-DA
Step 6-DA
Step 7-DA
Step 8-DA
Step 9-DA
Step 10-DA
EXIT DIAGNOSTICS
Step 4-DA
Step 5-DA
5. All Diagnostic values can be reset to 0 (zero). See bold type on page 7 for procedure.
Step 1-DA
Step 2-DA
Step 3-DA
Step 6-DA
Step 7-DA
Step 8-DA
Step 9-DA
Step 10-DA
EXIT DIAGNOSTICS
Step 4-DA
Step 5-DA