Page 11
Step 1-NA
Step 4-NA
Step 5-NA
EXIT INSTALLER
DISPLAY SETTINGS
Step 2-NA
Step 3-NA
Installer Display Settings
STEP 1-NA
– Press NEXT and
simultaneously for 3 seconds.
STEP 2-NA
– Hardness:
Set the amount of hardness in grains of hardness as
calcium carbonate per gallon using the
or
buttons. The default is 20 with
value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon
can be increased if soluble iron needs to be reduced. This display will show “–
nA–” if “FILTER” is selected in Step 2-FS (page 10) or if “AUTO” is not selected
in Step 6-SS (page 8). Press NEXT to go to step 3-NA. Press REGEN to exit
Installer Display Settings.
STEP 3-NA
– Day Override:
When Gallon Capacity is set to “oFF” in Step 6-SS
(page 8) or Step 5-FS (page 10), Day Override sets the number of days
between regenerations. When Gallon Capacity is set to “AUTO” or to a number,
Day Override sets the maximum number of days between regenerations. Set
Day Override using
or
buttons:
— number of days between regeneration (1 to 28) – a regeneration initiation
will be called for on that day even if a sufficient number of gallons were not
used to call for a regeneration; or
— “oFF” – regeneration initiation is based solely on gallons used.
Press NEXT to go to step 4-NA. Press REGEN to return to the previous step.
STEP 4-NA
– Next Regeneration Time (hour):
Set the hour of day for
regeneration using
or
buttons. AM/PM toggles after 12. The default time is
2:00 a.m. This display will show “REGEN on 0 GAL” if “on 0” is selected in Step
9-SS (page 8) or Step 7-FS (page 10). Press NEXT to go to step 5-NA. Press
REGEN to return to the previous step.
STEP 5-NA
– Next Regeneration Time (minutes):
Set the minutes of day for
regeneration using
or
buttons. This display will not be shown if “on 0” is
selected in Step 9-SS (page 8) or Step 7-FS (page 10). Press NEXT to exit
Installer Display Settings. Press REGEN to return to the previous step.
To initiate a manual regeneration immediately, press and hold the REGEN button
for 3 seconds. The system will begin to regenerate immediately. The control
valve may be stepped through the various regeneration cycles by pressing the
REGEN button.