User Display Settings 

General Operation 

When the system is operating, one of two 

displays will be shown. Pressing the NEXT 

button will alternate between the displays. 

One of the displays is always the current time 

of day. The second display is one of the 

following: days remaining or capacity 

remaining. Days remaining is the number of 

days left before the system goes through a 

regeneration cycle. Capacity remaining is the 

number of gallons that will be treated before 

the system goes through a regeneration 

cycle. The user can scroll between the 

displays as desired.

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN 

TODAY” will appear on the display. 

When water is being treated (i.e. water is flowing through the system) the word “SOFTENING” or “FILTERING” 

flashes on the display if a water meter is installed. 

Regeneration Mode 

Typically, a system is set to regenerate at a time of low water usage. An example 

of a time with low water usage is when a household is asleep. If there is a 

demand for water when the system is regenerating, untreated water will be used. 

When the system begins to regenerate, the display will change to include information about the step of the 

regeneration process and the time remaining for that step to be completed. The system runs through the steps 

automatically and will reset itself to provide treated water when the regeneration has been completed. 

Manual Regeneration 

Sometimes there is a need to regenerate the system 

sooner than when the system calls for it, usually referred to 

as manual regeneration. There may be a period of heavy 

water usage because of guests or a heavy laundry day. 

When the regeneration time option is set to “NORMAL” or “ on 0,” press and release the REGEN button 

to initiate a manual regeneration at the preset delayed regeneration time,  The words “REGEN TODAY” will flash on 

the display to indicate that the system will regenerate at the preset delayed regeneration time. If the REGEN button 

is pressed in error, pressing the button again will cancel the request. 

NOTE: If the regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN TODAY” 

will not activate if the REGEN button is pressed.

To initiate a manual regeneration immediately, press and hold the REGEN button for 3 seconds. The system will 

begin to regenerate immediately. The request cannot be cancelled.

NOTE: For softeners, if the brine tank does not contain salt, fill with salt and wait at least 2 hours before regenerating. 

OR

REGEN TODAY 

will be displayed if 

a regeneration is 

expected “Tonight.”

REGEN TODAY 

will flash if a

regeneration is 

expected “Tonight.”

Summary of Contents for TECH Series

Page 1: ...I n c O P E R A T I O N I N S T R U C T I O N M A N U A L TECH SERIES CONTROL VALVES F I L T E R S S O F T E N E R S C O N D I T I O N E R S 1 INCH TECH SERIES CONTROL VALVE MODEL WS1 1 25 INCH TECH SERIES CONTROL VALVE MODEL WS1 25 APRIL 2016 ...

Page 2: ...Clock Options 7 General Instructions 8 Softener Setup 9 Table 8 Softener and Filter Setting Options 10 Filter Setup 11 Installer Display Settings 12 User Display Settings 12 General Operation 12 Regeneration Mode 12 Manual Regeneration 13 Set Time of Day 13 Power Loss 14 Error Message 14 Diagnostics 15 Valve History 16 Drawings and Part Numbers 16 Front Cover and Drive Assembly 17 WS1 Drive Cap As...

Page 3: ...r tube can be cut 0 5 inch above to 0 5 inch below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve The AC adapter power pack is for dry location use only The control valve remember...

Page 4: ...reated water is still available For example If a downflow filter regeneration time is set for 2 00 a m with the prefill option selected then the fill cycle occurs at 12 00 a m and the start of the backwash cycle occurs at 2 00 a m There is only one rinse Backwashes can be set to NORMAL or LONGER The option selected will apply to all backwashes Tables 5 and 6 page 5 show the length of the cycles wh...

Page 5: ...ity should be set to oFF 2 See Installer Display Settings Step 3 NA page 11 Softener Setup Step 6 SS page 8 and Filter Setup Step 5 FS page 10 for explanations of Day Override and Gallon Capacity WS1 WS1 25 Single Backwash WS1 WS1 25 Double Backwash NORMAL LONGER NORMAL LONGER Backwash 14 16 8 12 Regenerate 60 60 60 60 2nd Backwash 10 12 Rinse 8 10 8 10 Total 82 86 86 94 WS1 WS1 25 Single Backwash...

Page 6: ...ing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds A unique feature of this control valve is the ability to display actual water usage for the last 63 days The values are initially stored as This means the value is unk...

Page 7: ...isplay Any changes made prior to the five minute time out are incorporated The one exception is the current flow rate display under the diagnostic procedure The current flow rate display has a 30 minute time out feature To quickly exit Softener Setup Filter Setup Installer Display Settings Diagnostics or Valve History press SET CLOCK Any changes made prior to the exit are incorporated All informat...

Page 8: ...capacity and water hardness oFF bases regeneration on Day Override in Step 3 NA page 11 or number of gallons 20 to 50 000 gallons See Table 8 page 9 for more detail 3 Press NEXT to go to Step 7 SS Press REGEN to return to the previous step STEP 7 SS Refill Set refill option using or buttons PoST to refill the brine tank after the final rinse or PrE to refill the brine tank two hours before the reg...

Page 9: ...ons is reached AUTO on 0 oFF Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when gallons capacity reaches 0 Any number on 0 oFF Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of reg...

Page 10: ...h LONGER for one longer backwash 16 minutes or LONGER 2 for two longer backwashes 12 minutes each See Tables 5 and 6 page 5 for additional details Press NEXT to go to Step 5 FS Press REGEN to return to the previous step STEP 5 FS Gallons Capacity Set gallons capacity using or buttons oFF bases regeneration on Day Override in Step 3N page 11 or number of gallons 20 to 50 100 gallons See Table 8 pag...

Page 11: ...mber of days between regeneration 1 to 28 a regeneration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration or oFF regeneration initiation is based solely on gallons used Press NEXT to go to step 4 NA Press REGEN to return to the previous step STEP 4 NA Next Regeneration Time hour Set the hour of day for regeneration using or b...

Page 12: ...egeneration process and the time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water...

Page 13: ... Step 3 UD STEP 3 UD Current Time minutes Set the minutes of the day using or buttons Press NEXT to exit Set Clock Press REGEN to return to previous step Power Loss If the power goes out the system will keep time for up to 8 hours or until the battery is depleted If a power outage of more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset The ...

Page 14: ...aximum number of gallons treated for the last 63 days This display will show dashes if a water meter is not installed Press NEXT at any time to go to Step 6 DA Press REGEN to return to the previous step STEP 6 DA Flow Rate current Turn the water on at one or more taps in the building The flow rate in gallons per minute will be displayed If flow stops the value will fall to 0 zero in a few seconds ...

Page 15: ...STEP 4 VH Gallons total used since start up This display shows the total gallons treated since start up This display will equal 0 zero if a water meter is not installed Press NEXT to go to Step 5 VH Press REGEN to return to the previous step STEP 5 VH Days total since start up This display shows the total days since start up Press NEXT to go to Step 6 VH Press REGEN to return to the previous step ...

Page 16: ... VAC 230 VAC Supply Frequency 60 Hz 50 Hz Output Voltage 12 VAC 12 VAC Output Current 500 mA 500 mA Drawing No Part No Description Quantity 1 LC V3175 01 WS1 Front Cover Assembly 1 LC V3002 WS1 Drive Assembly 1 2 LC V3107 01 WS1 Motor 1 3 LC V3106 01 WS1 Drive Bracket and Spring Clip 1 4 LC V3108 10BOARD WS1 PC Board XMEGA Replace 1 5 LC V3110 WS1 Drive Reducing Gear 12 x 36 3 6 LC V3109 WS1 Drive...

Page 17: ...ty 1 LC V3005 02 WS1 Spacer Stack Assembly 1 2 LC V3004 Drive Cap Assembly 1 3 LC V3178 WS1 Drive Backplate 1 4a LC V3011 WS1 Piston Downflow Assembly 1 4b LC V3011 01 WS1 Piston Upflow Assembly 1 5 LC V3174 WS1 Regenerant Piston 1 6 LC V3135 O ring 228 1 7 LC V3180 O ring 337 1 8 LC V3105 O ring 215 Distributor Tube 1 Not Shown LC V3001 WS1 Body Downflow Assembly 1 LC V3001 02 WS1 Mixing Valve Bo...

Page 18: ...sembly 1 4b LC V3011 01 WS1 Piston Upflow Assembly 1 5 LC V3174 WS1 Regenerant Piston 1 6 LC V3135 O ring 228 1 7 LC V3180 O ring 337 1 8 LC V3358 O ring 219 Distributor Tube Opening 1 32 inch 1 LC V3357 O ring 218 Distributor Tube Opening 32mm 1 Not Shown LC V3020 WS1 25 Body Downflow Assembly Distributor Tube Opening 1 32 inch 1 LC V3020 01 WS1 25 Mixing Valve Body Downflow Assembly Distributor ...

Page 19: ...iston is black and amber NOTE The WS1 downflow piston is a solid amber color The WS1 upflow piston is black and amber 1 25 inch 1 5 inch Spacer Color Black Spacer Color Gray 1 5 inch 1 25 inch Black Plug Spacer Color Gray 1 25 inch DOWNFLOW BACKWASH UPFLOW 1 25 inch Gray Plug Gray Ring Gray Distributor O ring Retainer NOTE The WS1 downflow piston is a solid amber color The WS1 upflow piston is bla...

Page 20: ... U F F C I T Y B O U L E V A R D E L G I N I L 6 0 1 2 0 U S A T E L E P H O N E 8 4 7 8 8 8 6 9 0 0 F A C S I M I L E 8 4 7 8 8 8 6 9 2 4 E M A I L i n f o s w t w a t e r c o m W E B S I T E w w w s w t w a t e r c o m FORM TECH MANUAL EFFECTIVE APRIL 2016 ...

Reviews: