13
Manufacturer reserves the right to alter specifications
Fan control
To change the fan setting
Pressing the + or - buttons on the blue fan
symbol changes the fan speed. The change is
indicated in the upper left diode scale.
Forced fan
Additional fan capacity. When you need to
have maximum ventilation. For example, in the
bath room or if shower is frequently used. This
function can also be activated via an external
switch.
Active Fan
Good with increased ventilation if you have
guests at home or to cool the house during hot
days. Active mode can also be good last pe-
riod before changing the filter to compensate
the filter pressure drop. Remember that energy
consumption is increasing and changing filters is
the best energy savings.
Normal Fan
Standard setting.
Passive Fan
Lowers fan speed, can be used during the day
when house are empty. The passive mode stops
any heating exept recovery.
Fan away
Save energy by reducing ventilation when you
go away. This function can also be activated
for example by house alarm or other external
switch. The away mode stops any heating exept
recovery.
Alarms and Operations
LEDs for Alarm and Drift (operation) flashes in
different ways depending on which alarm has
been triggered.
Numeric display indicates the alarm code. See
alarm list on page 26. Contact your installer for
more information about the action.
Fan- & Temperature controls
Filter alarm
If alarm code 12 is displayed, the filters needs
to be replaced! Contact Luftmiljö AB and order
new filters. You will receive a new filter sent
home when it’s time to change!
Form for filter subscription is available on our
website: www.luftmiljo.se. Or contact us and we
will send forms to you. You can also order filters
by contacting your installer.
If you do not replace the filters, the unit will
stop after a certain time!
Temperature control
In order to set the temperature
Pressing the + or - buttons on the red tempera-
ture indicator changes the temperature control.
The change is indicated in the lower right diode
scale.
• The green light indicates that the normal
temperature is selected. The unit delivers the
temperature set at the installation of the unit.
• The yellow light indicates that Eco is chosen,
for a more economical operation.
• The blue light at the bottom of the steps
indicates that Cool is selected. The auxiliary
heater is switched off and the cooling fun-
ction will start if installed.
Normal
Warmest position for maximum comfort.
Eco
Heat setting by 1 degree lower temperature
.
Cool
No heat is allowed. Provides cooler inlet tem-
perature at hot days. Heat recovery is striving
to maintain the set temperature. In Normal and
Eco seems exchanger for maximum heat re-
covery. The Cool operates to cooling recovery,
when the outdoor temperature falls below the
setpoint in heat recovery mode to maintain the
setpoint.