Section II: Installation
2.0.INS.SL-212
100 SERIES SUB-FRAME CRITICAL DIMENSIONS
LIFT BAR DETAIL
NOTE:
1.
A STRUCTURAL JIB CONTACT POINT LOCATED AS LOW AS ALLOWABLE ON THE CONTAINER FRONT IS REQUIRED.
2.
THIS DRAWING PROVIDES THE CRITICAL SUB-FRAME DIMENSIONS FOR COMPATABILITY WITH THE SWAPLOADER HOOK
LIFT HOIST. IT IS THE SUB-FRAME SUPPLIER’S RESPONSIBILITY TO PROVIDE A SUB-FRAME OF SUFFICIENT CAPACITY
WHICH PROPERLY SUPPORTS THE BODY/CONTAINER WHEN USED WITH THE HOOK LIFT HOIST.
200 SERIES SUB-FRAME DIMENSIONS
HOIST COMPATABILITY
A
SL-95/105
82 1/2” [2096 mm]
SL-125/145/180/185/212
95 1/2” [2418 mm]
2-12