www.swstahl.de
SW-Stahl GmbH
An der Hasenjagd 3
D-42897 Remscheid
Tel. +49 (0) 2191 / 46438-0
Fax +49 (0) 2191 / 46438-40
E-Mail: [email protected]
BEDIEUNUNGSANLEITUNG
/ INSTRUCTION
MANUAL
S3249
Commissioning:
1. Before operation, put a few drops of acid- and resin-free pneumatic oil in the air inlet of the tool.
2. Before connecting the tool, clean the couplers and hoses by blasting them briefly with air. Make sure
hose and couplers have a sufficient diameter.
3. The operating pressure measured under load at the tool air inlet should be 6.3 bar. A higher pressure
means greater wear and can cause damage to the tool. A fall in pressure to 5.5 bar means extreme
loss of power.
4. Good air quality is vital for any pneumatic tool. The air must be clean, dry and lubricated. The best
solution is a complete maintenance unit comprising an air filter, regulator and oil-fog lubricator which is
no more than 6-8 m away from the tool. The oiler should be set to 3-6 drops per minute (inspection
glass). The length of the hose between tool and maintenance unit should not exceed 8 m.
5. We recommend using a central oiler unit for optimum tool lubrication. Up to 80% oil can be saved,
which also improves the quality of the air inhaled by the user of course, since no excess oil is expelled
to the air.
6. The hammer mechanism of the impact screwdriver should be lubricated lightly after 60 working hours at
the latest. Too much grease will impair the power of the impact screwdriver since the hammer
mechanism will become sticky.
7. If the tool is not to be used for a longer period, it must be lubricated thoroughly before storage.
Before re-use, please heed points 1 and 2.
S3249:
8. The direction of rotation can be adjusted by turning the lever.
Clockwise = F / Anti-clockwise = R
9. Output can be adjusted in three stages by using the control dial.