Users Manual Area Scan Cameras SVSGigE
Page 46
Users Manual –evo1050, evo2050, evo2150, evo4050, evo4070, evo8050 and evo12040
© SVS-VISTEK GmbH
13
TECHNICAL DATA
An easy logic allows control of the camera by different signals to achieve optimum im-
age quality. However Truesense defect specification applies.
13.1
CCD used/cosmetic issues:
13.1.1
Sensors:
•
Truesense KAI 01050M/C 1024 x 1024 pixel
•
Truesense KAI 02050M/C 1600 x 1200 pixel
•
Truesense KAI 02150M/C 1920 x 1080 pixel
•
Truesense KAI 04050M/C 2336 x 1752 pixel
•
Truesense KAI 04070M/C 2048 x 2048 pixel
•
Truesense KAI 08050M/C 3320 x 2496 pixel
•
Truesense KAC 12040M/C 4000 x 3000 pixel
13.1.2
Cosmetic Specs
13.1.2.1
KAI 01050
Up to 110 pixel dead or out of PRNU spec.
No cluster. Column defects: 0.
13.1.2.2
KAI 02050 Class I
Cluster allowed. Cluster may contain up to 10 pixel out of PRNU spec.
8 cluster allowed. Point defects: 25 pixel dead or out of PRNU spec. (Column
defects: 0.
13.1.2.3
KAI 02150 Class I
Cluster allowed. Cluster may contain up to 10 pixel out of PRNU spec.
8 cluster allowed. Point defects: 25 pixel dead or out of PRNU spec. (Column
defects: 0.
13.1.2.4
KAI 04050
Cluster allowed. Cluster may contain up to 10 pixel out of PRNU spec.
8 cluster allowed. Point defects: 450 pixel dead or out of PRNU spec. (Column
defects: 0.
13.1.2.5
KAI 04070
Cluster allowed. Cluster may contain up to 10 pixel out of PRNU spec.
8 cluster allowed. Point defects: 80 pixel dead or out of PRNU spec (Column de-
fects: 0.