Users Manual Area Scan Cameras SVSGigE
Page 32
Users Manual –evo1050, evo2050, evo2150, evo4050, evo4070, evo8050 and evo12040
© SVS-VISTEK GmbH
Also a strobe can be controlled, the total time sequence can be seen in the following
drawing.
SeqInterval 0
SeqInterval 1
SeqInterval 2
ExpStart 0
ExpStop 0
ExpStart 1
ExpStop 1
StrobeStart 0
StrobeStop 0
PWM 100%
PWM 50%
•
StrobeStart and StobeStop determine the duration of the output signal
•
Within this time a pulse width modulation can control the intensity of an illumination,
for example
o
PWM100% = full time output
o
PWM50% = 50% output
•
For each sequence up to 4 PWM’s can be configured
•
These PWM’s are output data line and have to be directed to a physical output using
“Camera IO configuration” in “Camera” menu”. Otherwise there is no physical reaction
in a connected unit device.
•
Setup for physical PWM output is shown on the next page.
!! As told before the sequencer has its own trigger management. Software trigger is
done with SNAP. For hardware trigger IN0 to IN2 are selectable.