The “Multicast” group box will display the packet size that applies to the running im-
age data stream.
The listening application has to have at least that packet size
available (jumbo frames) in order to properly connect to the image data
stream
.
After selecting the multicast camera in the camera list of the discovery dialog the OK
button can be clicked or the camera entry can be double clicked in order to connect to
the already running image data stream.
Since the listening application does not have control access, all controls in the ‘SVCam
Settings’ dialog will be disabled except the Close button.
3.3.7
Displaying live images
Connect a SVS-GigE-Camera with a network cable to your PC or network switch.
Plug in the RJ 45 Camera connector and then plug in the AC/DC power supply.
Wait 15 seconds until the green LED at the RJ45 connector of the Camera blinks
sometimes. Then start “SVCapture.exe”.
After start of “SVCapture.exe”