SVS-VISTEK
Feature-Set
77
Strobe Timing
7.3.2.1.1
Exposure Delay
A value, representing the time between the (logical) positive edge of
trigger pulse and start of integration time. Unit is 1
μ
s. Default is 0
μ
s.
7.3.2.1.2
Strobe Polarity
Positive or negative polarity of the hardware strobe output can be
selected.
7.3.2.1.3
Strobe Duration
The exposure time of LED lights can be set in
µ
sec. The min duration is 1
µ
sec. The longest time is 1 second.
7.3.2.1.4
Strobe Delay
The delay between the (logical) positive edge of trigger pulse and strobe
pulse output can be set in
µ
sec. Unit is 1
μ
s. Default is 0
μ
s.