Figure 70: Illustration of schematic wiring with 4IO model using the break out box (matrix)
The pulseloop module
A fully programmable timer/counter function with four individual pulse
generators (pulseloop0 - 3) that can be combined with all SVCam I/O
functions, as well as physical inputs and outputs. All timing settings are
programmable in 15ns intervals.
P
R O G R A M M A B L E P A R A M E T E R S
:
>
Trigger source (hardware or software)
>
Edge or level trigger (HW trigger)
>
Pulse output starting on low or high level
>
Pre and post duration time
>
Number of loops
E
X A M P L E A P P L I C A T I O N S
Initiated by an external trigger, the camera drives an LED illumination
directly from the open drain output and initiates the camera exposure
after a pre-defined delay.