SVS-VISTEK
Feature-Set
59
7.3.1
Assigning I/O Lines – IOMUX
The IOMUX is best described as a switch matrix. It connects inputs, and
outputs with the various functions of SVCam I/O. It also allows combining
inputs with Boolean arguments.
Figure 54: "IN0" connected to "debouncer"
The input and output lines for Strobe and Trigger impulses can be
arbitrarily assigned to actual
. Individual assignments can be
stored persistently to the EPROM. Default setting can be restored from
within the Camera.
Note:
If you connect the camera with a non-
SVS-Vistek GigEVision client, you might
not see the clearnames of the lines, but
only line numbers. In this case, use this
list of line names
LineSelector
translation
Line0
Output0
Line1
Output1
Line2
Output2
Line3
Output3
Line3
Output4
Line5
Uart In
Line6
Trigger
Line7
Sequencer
Line8
Debouncer
Line9
Prescaler
Line10
Input0
Line11
Input1
Line12
Input2
Line13
Input3
Line14
Input4
Line15
LogicA
Line16
LogicB
Line17
LensTXD
Line18
Pulse0
Line19
Pulse1
Line20
Pulse2
Line21
Pulse3
Line22
Uart2 In
Summary of Contents for EC02 Series
Page 16: ...SVS VISTEK Getting Started 16 Installation will proceed 8 Installation completed ...
Page 29: ...SVS VISTEK Dimensions 29 6 1 2 side Left 6 1 3 Bottom ...
Page 30: ...SVS VISTEK Dimensions 30 6 1 4 Back 6 1 5 Cross Section ...
Page 54: ...SVS VISTEK Feature Set 54 ...
Page 61: ...SVS VISTEK Feature Set 61 Figure 56 I O Lines with open end indicate physical in and outputs ...
Page 116: ...SVS VISTEK Terms of warranty 116 ...
Page 119: ...SVS VISTEK Troubleshooting 119 Space for further descriptions screenshots and log files ...