7
Periodic checks
Periodic checks are normally carried out yearly to detect and remedy any faults. Check
the winch and its fixings and the condition and fixing of the rope and hooks. See also
Page 7.
Repairs
Winches must not be modified or the lifting purpose etc. altered. Repairs must be
carried out by specialists. Replace damaged parts with original SVERO parts. Order
them through your dealer.
Replacing wire rope
When replacing the wire rope, be sure to choose
the right rope (diameter and construction) as
indicated in "Technical data". Insert the end of the
new rope in the hole in the drum and pull it
towards the integral clamp with Allen bolt, see Fig.
10. Wind it on without twisting and ensure that the
rope lies evenly and closely spaced, as shown on
Fig. 3.
Inspection and maintenance
Daily
Quarterly
Yearly
Inspection point
Checks and remedies
X
Labelling/rating
plate
Visual. If the label is hard to
read or missing – order a new
one.
X
Installation
Secure fixing. Bolts must be well
tightened.
X
Foundation frame
Check it is not deformed or
otherwise damaged
X
X
Rope/rope drum
Rope winding must be even.
Max. permitted angular
deviation 1.5
°
sideways
X
X
Rope
The rope must not be damaged,
corroded or kinked. Otherwise
replace. *) Check fixing to rope
drum yearly.
Fig 10 Fixing the wire rope to the
drum.
Summary of Contents for 1 SA
Page 10: ...10 NB 07 03 09 Appendix 1...
Page 11: ...11 Appendix 2...
Page 12: ...12...
Page 22: ...22 NB 2009 03 07 Bilaga 1...
Page 23: ...23 Bilaga 2...
Page 24: ...24...
Page 34: ...34 NB 07 03 2009 Vedlegg 1...
Page 35: ...35 Vedlegg 2...
Page 36: ...36...
Page 47: ...47 NB 2009 03 07 Liite 1...
Page 48: ...48 Liite 2...