Connect the digital tester to the 15V and GND-1 check pins and adjust VR3 so that the voltage is 15.0V.
Connect the digital tester to the 70V and GND-1 check pins and adjust VR2 so that the voltage is 70.0V, when J3
connector is not connected.
Connect the digital tester to the 12V and GND-1 check pins and verify the voltage is 12.0±0.6V.
Connect the digital tester to the 5V-1 and GND-1 check pins and verify the voltage is 5.0±0.25V.
Connect the digital tester to the 5V-2 and GND-2 check pins and verify the voltage is 5.0±0.25V.
Connect the oscilloscope to the FRQ and GND-P check pins and adjust the waveforms at VR1 so that the below
is shown.
The value of frequency counter is 115.0 kHz.
8.69μsec(115.0 kHz)
Connect the oscilloscope to the 70V and GND-1 check pins and the Dummy Load between the J3-No.4 (70V) and
No.3 (GND).
And adjust VR4 voltage rate that starts to degrease at 150Ω and keeps it not to degrease at 160Ω.
Reference: Power Reduction Control (TX POWER)
TX POWER
Voltage (V)
C
50V
±
5
%(
approx.47
〜
53V
)
B
31V
±
10
%(
approx.28
〜
34V
)
A
21V
±
20
%(
approx.16
〜
25V
)
-32-
Adjust the voltage, 70V on the Power Supply PCB (No.703) for S-1800 Hull Unit
(Reckless adjustment may cause serious problem.)
Summary of Contents for S-1800H80/180
Page 44: ...N o 6 8 8 A...
Page 46: ......
Page 48: ......
Page 50: ...NO 748 H SYNC CH1 J15 3pin GND V SYNC CH2 J15 4pin GND...
Page 53: ......
Page 55: ...NO 654 FRQ CH1 FRQ GND P...
Page 64: ......
Page 67: ......
Page 69: ......
Page 70: ...180kHz HULL UNIT CIRCUIT DIAGRAM WAVE FORMS 180 kHz...
Page 73: ......
Page 75: ......
Page 81: ...70V...
Page 83: ...NO 703 CH1 FRQ GND P...
Page 90: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ...HULL UNIT ASSEMBLY DRAWING...