PERIODIC MAINTENANCE 2-20
BATTERY SOLUTION LEVEL CHECK
Battery solution level should be between the UPPER level and
LOWER level.
If the level is low, add distilled water only.
B
Once the battery has been initially serviced, NEVER
add diluted sulfuric acid, or you will damage the bat-
tery. Follow the battery manufacture’s instructions for
specific maintenance procedures.
BATTERY SOLUTION GRAVITY CHECK
Measure the gravity of battery solution using a hydrometer.
Battery solution gravity : 1.28 at 20°C
09900-28403 : Hydrometer
BOLT AND NUTS
Inspect initially after 20 hours (1 month) and every 100
hours (6 months) thereafter
Check that all bolt and nuts listed below are tightened to their
specified torque.
z
ITEM
Tighten torque
N . m
kg-m
lb.-ft.
Cylinder head cover bolt
10
1.0
7.2
Intake manifold bolt / nut
11
1.1
7.9
23
2.3
16.5
6 mm
8 mm
Flywheel bolt
ECM ground bolt
Power unit mount bolt
Clamp bracket shaft nut
43
4.3
31
Gear case bolt
Propeller nut
55
5.5
40.0
200
20.0
145
10
1.0
7.2
23
2.3
16.5
50
5.0
36.0
8 mm
10 mm
23
2.3
16.6
Summary of Contents for DF 40
Page 1: ...99500 87J00 01E ...
Page 108: ......
Page 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Page 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Page 272: ... _ _ r ...
Page 279: ......
Page 367: ... ...
Page 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...