![Suzuki DF 40 Service Manual Download Page 113](http://html.mh-extra.com/html/suzuki/df-40/df-40_service-manual_1408856113.webp)
4-7 ELECTRICAL
TROUBLESHOOTING
NOTE:
Before troubleshooting the electric starter system, make sure of the following :
• Battery is fully charged.
• All cables / wires are securely connected.
• Shift is in “NEUTRAL” position.
Circuit check schematic
Check starter motor.
(See page 4-14.)
Sub cable
1
+
-
3
Starter motor
GND
Ignition switch
Neutral switch
ST
BAT
GND
GND
Neutral
switch
30A Fuse
GND
GND
Battery
Starter motor relay
2
Starter motor will not run.
Check for relay “click” sound when turning
ignition switch to “START”.
Is there “click” sound?
Measure voltage at terminal
2
with ignition
switch at “START”. It must be above 12 V.
Is result OK?
Measure voltage at terminal
3
with ignition
switch at “START”. It must be above 12 V.
Is result OK?
Starter motor failure
Sub cable failure
Measure voltage at
terminal
1
. It must be
above 12V.
Is result OK?
Check 30A fuse and
fuse case.
(See page 4-2.)
Is result OK?
Check ignition switch
function.
(See page 4-8.)
Is result OK?
Check function of
both neutral switches.
(See page 4-9.)
Is result OK?
Check starter motor
relay.
(See page 4-10.)
Starter motor relay
failure
Battery cable
failure
30A fuse or
fuse case failure
Ignition switch
failure
Neutral switch
failure
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
Summary of Contents for DF 40
Page 1: ...99500 87J00 01E ...
Page 108: ......
Page 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Page 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Page 272: ... _ _ r ...
Page 279: ......
Page 367: ... ...
Page 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...