4-1 ELECTRICAL
BATTERY CHARGING SYSTEM
OUTLINE
The battery charging system circuit is illustrated below.
It is composed of the BATTERY CHARGE COIL, RECTIFIER
& REGULATOR and BATTERY.
The three phase AC current generated from battery charge coil
is converted by the rectifier & regulator into regulated DC cur-
rent which is used to charge the battery.
OUTPUT
REGULATED
VOLTAGE
216 W
14.5 – 15.5 V
Battery charge coil
Alternator
(Magneto)
HIC
Rectifier & regulator
Battery (12V)
To Starter motor
Starter
motor
relay
30A Fuse
To PTT switch
To ECM main relay
To Ignition switch
B
Y
Y
Y
W
W
W
R
+
-
W
W
W