Maintenance of the MFL
SDS-35
31
5004522-000 Rev. 03
SUZOHAPP
7.2 Level 2 Maintenance
Although a basic level of cleaning has been performed in the Level 1
maintenance, over time, additional cleaning is required to get tougher
dirt off the banknote path. Dust and contaminants carried by
banknotes will start accumulating deeper along the banknote path
and it will be tighter and harder to reach areas.
Level 2 maintenance involves thorough inspection and cleaning of
the validator unit and the cash box. This maintenance is handled by
trained technical personnel and is performed at the end of 9 months
or 90,000 bill insertions whichever comes first.
7.3 Level 3 Maintenance
Level 3 of preventative maintenance restores the unit from the effects
of temperature cycling over a period of time as well as from operating
wear and tear. This must be performed at the end of 3 years or
270,000 banknote insertions whichever comes first. The maintenance
must be done at an authorised service centre location.