6.3.3
Installing the Electrical Controller
IMPORTANT
Ensure sufficient cable length for the lifting elements when positioning the elec-
trical controller. The mounting material needed for this is individual and not included in the scope
of delivery.
Mount the electrical controller with four screws to the workplace.
When attaching, insert metal washers between the screws and the electrical controller to pre-
vent damage to the controller housing.
Do not mount / operate the controller:
▪
above or in front of heat sources (e.g. radiators),
▪
at locations exposed to direct incidence of sunlight,
▪
at or near easily inflammable materials or
▪
near high-frequency equipment (e.g. transmitters, radiation equipment or similar devices).
Make sure that connecting cables do not have kinks or are not exposed to mechanical stress.
For protection against over-voltage that may occur during thunderstorms, it is recommended that
you install over-voltage protection. Get advice from an electrical installation engineer.
IMPORTANT
Observe and follow the aspects given below in the course of installation:
Select a centralized installation location. Empirical values have demonstrated that this offers
the easiest option for the cabling.
Fix the controller tightly with screws (Figure 11). In this way, you avoid malfunctions caused by
loose plug-in connections or undesirable noise development.
During installation, make sure that the controller is freely accessible even after installation.
This enables ease of working in case you need to do service work.
Ensure that there is adequate air circulation during installation. There is, in fact, little heat de-
veloped by the controller, but nonetheless, it exists.