Installation
SUSPA Movotec SMS - Installation Instructions
Page 25
Select for the fastening screws M5 with class 8.8 or higher.
IMPORTANT
In order to avoid damage to the lifting elements, the screws must not be thread-
ed more than 7 mm into the lifting element housing.
Figure 9 Maximum screw depth
Fasten each lifting element with four M5 screws of the proper length to the frame of the
workplace (recommended installation depth: 5-7 mm)
Check the mounting screws of the lifting elements in order to ensure that they are fastened
securely to the workplace. Note that you do not over-tighten the lifting element-mounting
screws (recommended tightening torque: 4,0-4,5 Nm)
Make sure that the electrical lines of each leg of the workplace can be laid without putting
them under tension by maintaining the permissible bending radius of 57 mm (single) and 86
mm (multiple). The electrical wires to the lifting elements are each 2.5 m long.
Screw the leveling feet (Optional) fully into the lifting elements.
Position the workplace properly again such that the leveling feet stand on the floor.
IMPORTANT
Take care to ensure that the workplace is not put down too abruptly in order to
avoid damaging the lifting elements.
max. 7 mm