![SurfRAID LC16 Series User Manual Download Page 46](http://html.mh-extra.com/html/surfraid/lc16-series/lc16-series_user-manual_1407259046.webp)
SurfRAID LC16 Series User’s
Manual
46
Appendix E. Creating Two LUN’s on the SurfRAID
LC16
1)
Build RAID as required (RAID 1, 3, 5…)
2) Enter Main Menu, First Select: RAID Parameters, Second Select: Array (1,2,3,4, etc), Third Select: Slice,
Fourth Select: Slice0. Youwill now see the whole size of your RAID system in (MB)
3)
Enter disk size for Slice0 (for example 100000 MB)
4)
Enter disk size for Slice1 (for example 33622 MB, then press Enter)
5)
When you are done entering the disk size for the Slice, you will need to update the NVRAM. Go
to Main Menu and NVRAM and select Update NVRAM, Select YES.
6) Return to the Main Menu, Select: SCSI/FC Parameters, Select Primary SCSI/FC and then LUN Map.
7)
Select Lun 0 mapping to Slice 0.
8) Return to the Main Menu, Select: SCSI/FC Parameters, Select Secondary SCSI/FC and then Lun Map.
9)
Select Lun 0 mapping to Slice 1.
10) After Lun mapping you will need to update the NVRAM again, Go to Main Menu and NVRAM
and select Update NVRAM, Select YES.
11) You will now need to restart the system. Go to Main Menu, Select NVRAM, then Restart, then
Yes.
12) After restarting, you will get Primary SCSI/FC mapping to Slice0, Secondary SCSI/FC mapping to Slice 1
a) Primary SCSI/FC (Slice 0 = 100000 MB) example.